Oregon Scientific Radar Detector BAR208HG User Manual

Weather Trends ..................................................... 7  
Advanced Weather Station  
with Atomic Time  
Moon Phase .............................................................. 7  
Backlight ................................................................... 7  
Reset.......................................................................... 7  
Precautions............................................................... 7  
Specifications ........................................................... 8  
About Oregon Scientific .......................................... 8  
EU-Declaration of Conformity ................................. 8  
Model: BAR208HG  
USER MANUAL  
CONTENTS  
Overview.................................................................... 2  
Front View ............................................................. 2  
Back View ............................................................. 3  
Remote Sensor ..................................................... 3  
Getting Started.......................................................... 3  
Insert Batteries ...................................................... 3  
Remote Sensor ......................................................... 4  
Sensor Data Transmission .................................... 4  
Clock.......................................................................... 5  
Clock Reception .................................................... 5  
Manually Set Clock ............................................... 5  
Weather Forecast ..................................................... 6  
Weather Warning Message...................................... 6  
Temperature and Humidity...................................... 6  
Ice Warning ........................................................... 6  
1
 
BAR208HG_M_EN_R3.indd  
1
8/9/07 9:13:28 AM  
REMOTE SENSOR (FIG 3)  
BACK VIEW (FIG 2)  
2
1
4
5
3
1. LED status indicator  
2. Wall mount hole  
3. Battery compartment  
4. RESET hole  
2
1
3
5. CHANNEL switch  
GETTING STARTED  
INSERT BATTERIES  
1. Remove the battery compartment.  
2. Insert the batteries, matching the polarities (see FIG  
1. °C / °F: Select temperature unit  
2).  
2. EU / UK: Select the nearest radio signal  
3. Press RESET after each battery change.  
3. RESET: Reset unit to default settings  
3
 
BAR208HG_M_EN_R3.indd  
3
8/9/07 9:15:28 AM  
LOCATION  
MEANING  
Clock / alarm and  
Main unit batteries low  
Indoor temperature area  
Outdoor temperature area Sensor batteries low  
REMOTE SENSOR  
The main unit can collect data from up to 3 sensors.  
To set up the sensor:  
1. Open the battery compartment (see FIG 3).  
2. Select a channel then press RESET.  
3. Close the battery door.  
1.5m(5ft)  
4. Place the sensor within 30 m (98 ft) of the main unit  
using the table stand or wall mount.  
TIP Ideal placements for the sensor would be in any  
location on the exterior of the home at a height of not  
more than 1.5 m (5 ft) and which can shield it from direct  
sunlight or wet conditions for an accurate reading.  
NOTE Use alkaline batteries for longer usage and  
consumer grade lithium batteries in temperatures below  
freezing.  
SENSOR DATA TRANSMISSION  
To search for a sensor:  
Press and hold  
+ MODE.  
The sensor reception icon in the remote sensor area  
shows the status:  
4
 
BAR208HG_M_EN_R3.indd  
4
8/9/07 9:14:04 AM  
ICON  
DESCRIPTION  
reception is unsuccessful, place your unit next to a window,  
press and hold to force another signal search.  
Main unit is searching for  
sensor(s).  
Clock signal reception indicator:  
STRONG SIGNAL WEAK SIGNAL  
A channel has been found.  
NO SIGNAL  
The sensor cannot be found.  
TIP The transmission range may vary depending on  
many factors. You may need to experiment with various  
locations to get the best results.  
MANUALLY SET CLOCK  
To set the clock manually, disable the signal reception  
first.  
CLOCK  
1. Press and hold MODE.  
CLOCK RECEPTION  
2. Press  
or  
to change the settings.  
3. Press MODE to confirm.  
4. The settings order is: time zone, 12/24 hr format, hour,  
minute, year, calendarmode(daymonth/monthday),  
This product is designed to synchronize its clock  
automatically with a clock signal.  
Slide EU / UK to select the signal received.  
month, day and language.  
EU: DCF-77 signal: within 1500 km (932 miles) of  
Frankfurt, Germany.  
Time zone offset sets the clock +/- 23 hours from the  
received clock signal time.  
UK: MSF-60 signal: within 1500 km (932 miles) of  
Anthorn, England.  
NOTE The language options are English (E), German  
(D), French (F), Italian (I), and Spanish (S).  
To enable / disable signal reception:  
Press and hold  
reception.  
to enable or  
to disable signal  
To select display mode:  
Press MODE to choose between clock with seconds /  
weekday / calendar / moon phase.  
NOTE Reception takes 2-10 minutes. If the signal is weak,  
it can take up to 24 hours to get a valid signal. If signal  
5
 
BAR208HG_M_EN_R3.indd  
5
8/9/07 9:14:09 AM  
WEATHER FORECAST  
Risk of foggy conditions  
Risk of icy conditions  
This product forecasts the next 12 to 24 hours of  
weather within a 30-50 km (19-31 mile) radius with a  
75% accuracy.  
Sunny  
TEMPERATURE AND HUMIDITY  
To toggle temperature unit:  
Press °C / °F.  
Partially Cloudy  
Cloudy  
To auto-scan between sensors:  
Press and hold  
for 3 seconds.  
+ MEM to display each sensor’s data  
Rainy  
To end press  
.
Snowy  
To toggle between current, minimum and maximum  
records for the selected sensor:  
WEATHER WARNING MESSAGE  
Press MEM repeatedly.  
The weather warning messages provide indications of  
probable circumstances that may arise based on the  
weather station’s calculations. The meanings for the  
warnings are illustrated below:  
To clear the records:  
Press and hold MEM.  
ICE WARNING  
Warning  
Meaning  
If the channel 1 sensor falls between 3°C to -2 °C (37°F  
to 28°F), LED indicator will flash, and will stop flashing  
once the temperature is out of this range.  
Risk of high temperatures  
Risk of fast wind speeds  
Risk of a storm  
6
 
BAR208HG_M_EN_R3.indd  
6
8/9/07 9:14:17 AM  
WEATHER TRENDS  
PRECAUTIONS  
The temperature, humidity and pressure trend icons are  
based on recent sensor readings.  
Do not subject the unit to excessive force, shock,  
dust, temperature or humidity.  
Do not cover the ventilation holes with any items such  
as newspapers, curtains etc.  
Do not immerse the unit in water. If you spill liquid  
over it, dry it immediately with a soft, lint-free cloth.  
Do not clean the unit with abrasive or corrosive  
materials.  
Do not tamper with the unit’s internal components.  
This invalidates the warranty.  
Only use fresh batteries. Do not mix new and old  
batteries.  
Images shown in this manual may differ from the  
actual display.  
When disposing of this product, ensure it is collected  
separately for special treatment.  
Placement of this product on certain types of wood  
may result in damage to its finish for which Oregon  
Scientific will not be responsible. Consult the furniture  
manufacturer’s care instructions for information.  
The contents of this manual may not be reproduced  
without the permission of the manufacturer.  
Do not dispose old batteries as unsorted municipal  
waste. Collection of such waste separately for special  
treatment is necessary.  
RISE  
STEADY  
FALL  
MOON PHASE  
In moon phase mode, press  
the years (2001 to 2099).  
or  
to scan through  
Full Moon  
New Moon  
Waxing Crescent  
First quarter  
Waning Gibbous  
Last quarter  
Waxing Gibbous  
Waning Crescent  
NOTE Star icons around the moon phase will be displayed  
from 6 o’clock in the evening to 6 o’clock the next morning.  
BACKLIGHT  
Press LIGHT to activate backlight for 5 seconds.  
RESET  
Please note that some units are equipped with a  
battery safety strip. Remove the strip from the battery  
compartment before first use.  
Press RESET to return to the default settings.  
7
 
BAR208HG_M_EN_R3.indd  
7
8/9/07 9:14:27 AM  
NOTE The technical specifications for this product and  
the contents of the user manual are subject to change  
without notice.  
ABOUT OREGON SCIENTIFIC  
more about Oregon Scientific products. If you’re in  
the US and would like to contact our Customer Care  
department directly, please visit: www2.oregonscientific.  
com/service/support  
SPECIFICATIONS  
TYPE  
DESCRIPTION  
OR  
MAIN UNIT  
L x W x H  
Call 1-800-853-8883.  
94 x 51 x 182.5 mm  
(3.70 x 2.01 x 7.19 in)  
For international inquiries, please visit:  
www2.oregonscientific.com/about/international  
Weight  
241 g (8.5 oz) without battery  
-5°C to 50°C (23°F to 122°F)  
0.1°C (0.2°F)  
Temperature range  
Resolution  
EU-DECLARATION OF CONFORMITY  
Hereby, Oregon Scientific, declares that this Advanced  
Weather Station withAtomic Time (Model: BAR208HG) is  
in compliance with the essential requirements and other  
relevant provisions of Directive 1999/5/EC. Acopy of the  
signed and dated Declaration of Conformity is available  
on request via our Oregon Scientific Customer Service.  
Signal frequency  
Humidity range  
Humidity resolution  
Power  
433 MHz  
25% - 95%  
1%  
3 x UM-3 (AA) 1.5 V batteries  
REMOTE UNIT (THGN132N)  
L x W x H  
50 x 22 x 96 mm  
(1.97 x 0.87 x 3.78 in)  
Weight  
62 g (2.22 ounces)  
without battery  
COUNTRIES RTTE APPROVAL COMPLIED  
CH  
All EC countries, Switzerland  
Transmission range  
Temperature range  
Humidity range  
Power  
30 m (98 ft) unobstructed  
-20°C to 60°C (-4°F to 140°F)  
25% - 95%  
N
and Norway  
1 x UM-3 (AA) 1.5 V battery  
8
 
BAR208HG_M_EN_R3.indd  
8
8/9/07 9:14:28 AM  

Milwaukee Sander 6065 User Manual
Murphy Switch M 6797B User Manual
NEC Flat Panel Television LCD6520L BK AV User Manual
NetComm Network Router NB2800 User Manual
NETGEAR Switch JFS516 User Manual
Niles Audio Universal Remote R 6L User Manual
NordicTrack Home Gym NEL70951 User Manual
Onkyo DVD Player DV S555 User Manual
Palsonic CD Player DVD2080HD User Manual
Panasonic Telephone KXTGM240S User Manual