Omnitron Systems Technology TV Converter Box FlexPoint GX T User Manual |
FlexPoint GX/T
DIP-SWITCHES
F/O Manual/Auto “MAN/AN” DIP-Switch:
LS
LS
it with the DC-DC Converter (Model # 4384)
WARNING!
Fiber
Fiber
Connector Type
Fiber Type
Distance
RX
TX
TX
TX
RX
TX
ST
SC
SFP
Setting this DIP-Switch to P1 Auto-Negotiate “AN” (factory
setting) enables the Fiber Port to determine duplex mode
automatically. If the connected device cannot provide
the proper signal to indicate its own mode of operation,
this DIP-Switch should be set to P1 Manual “MAN.” This
feature allows connections with legacy devices that do
not support auto-negotiation.
UTP
UTP
FlexPoint™ GX/T
10/100/1000 UTP to 100/1000X
Ethernet Media Converter
User Manual
(a)
UTP
Fiber
RX
UTP
Fiber
RX
SFP
MM
SM
SM
SM
SM
SM
-
220 / 550m 1
12km
-
-
4719-x
Before inserting the Power Adapter, verify
that the power on the unit is appropriate
for your AC line voltage source.
4706-x
4700-x
4701-x
4702-x
4703-x
4704-x
4705-x
-
-
-
-
-
-
4707-x
Normal Mode
Switch 1 Converter A
LS
Converter B Switch 2
LS
Loopback Mode
34km
-
-
-
-
Figure 1: Loopback Mode
80km
110km
140km
LINK MODES
(b)
INSTALLATION PROCEDURE
1.) Configure the appropriate FlexPoint GX/T DIP-Switch
settings.
In order to accommodate different user needs, the GX/T
supports four different link modes (see Fig. 2).
SM-SF
1310/1550
SM-SF
1550/1310
SM-SF
1310/1550
SM-SF
1550/1310
NOTE: When the fiber port is in Manual Mode, a link-up
may not occur with other devices. Both devices must be
set to the same mode (either Manual or Auto-Negotiate) for
the link-up to occur.
-
-
-
-
4710-x
4711-x
4712-x
4713-x
-
-
-
-
20km
20km
40km
40km
Switch 1 Converter A
LP
Converter B Switch 2
LP
In Link Segment (LS), a port transmits a Link signal
independently of any received Link at any other port. For
example, the UTP transmits a Link regardless of the fiber
receiving a Link [Fig. 2(a) & (b)].
2.) Connect the UTP port via a Category 5 or better cable
to a 10BASE-T, 100BASE-TX or 1000BASE-T Ethernet
device.
When set to auto-negotiation, the fiber port will
automatically reconfigure to manual mode when an auto-
negotiation connection cannot be established.
(c)
Power Adapter Kits (-x):
-0 = No power adapter included
-1 = 110-120 VAC/60 Hz (US plug)
3.) When using fixed fiber port models, connect the
appropriate multimode or single-mode fiber cable to the
fiber port of the installed module. It is important to ensure
that the transmit (Tx) is attached to the receive side of
the device at the other end and the receive (Rx) is attached
to the transmit side. Single-fiber (SF) media converter
models operate in pairs. The Tx wavelength must match
the Rx wavelength at the other end and the Rx wavelength
must match the Tx wavelength at the other end.
In Link Propagate (LP), a port transmits a Link signal only
when receiving a Link at its other port. For example, the
UTP transmits a Link only when receiving a Link at the
fiber port [Fig. 2(c)].
Switch 1 Converter A
LP
Converter B Switch 2
RFD+LS
F/O Speed “100/1000” DIP-Switch:
-2 = 100-240 VAC/50-60 Hz (IEC plug, no power cord)
The GX/T supports 100BASE-FX and 1000BASE-X SFPs.
This DIP-switch is used to configure the unit for the
speed of SFP used. Setting this DIP-switch to “1000”
enables the fiber port is accept 1000BASE-X SFPs. Setting
this DIP-switch to “100” enables the fiber port to accept
100BASE-FX SFPs. This DIP-switch is only available on
the SFP model.
For other power and fiber configurations, contact the factory.
DESCRIPTION:
1 62.5/125µm, 100/140µm multimode fiber up to 220m, 50/125µm
multimode fiber up to 550m. Refer to the fiber cable manufacturer for
multimode distance specifications.
The FlexPoint GX/T is a 10/100/1000BASE-T UTP to
1000BASE-X fiber media converter that supports jumbo
frames up to 10,240 bytes. The GX/T features Small
Form Pluggable (SFP) transceivers that support both
100BASE-FX and 1000BASE-X for interoperability with
Gigabit and Fast Ethernet fiber equipment.
In Remote Fault Detection + Link Segment (RFD+LS),
the fiber port transmits a Link signal only when receiving
a Link at the fiber port. As a result, fiber faults (no Link
received at the fiber) are looped-back and can be reported
to the network core [Fig. 2(d)].
(d)
Single-Fiber converters must be used in pairs. The Tx wavelength
on one end has to match the Rx wavelength on the other.
Switch 1 Converter A
LP
Converter B Switch 2
RFD+LP
POWER ADAPTER NOTICE:
4.) When using a GX/T SFP model, insert the SFP Fiber
transceiver into the Port 1 SFP receptacle on the GX/T.
1. This product should only be used with Omnitron Supplied
Power Unit model numbers 9113-PS [US] or 9115-PS
[Universal].
In Remote Fault Detection + Link Propagate (RFD+LP),
the UTP port transmits a Link signal only when receiving
a Link at the fiber port. The fiber port transmits a Link
signal only when receiving Link signals at both the fiber
port and the UTP port. As a result, fiber faults (no Link
received at the fiber) are propagated forward and looped
back for fault reporting at both the network core and the
customer location [Fig. 2(e)].
This DIP-switch is ignored when using Omnitron branded
SFPs. The GX/T automatically configures the fiber port
to the correct speed.
(e)
Both the fiber port and the UTP port support auto-
negotiation, an IEEE standard which defines how all the
communicating devices automatically perform their
configuration functions.
NOTE: The release latch of the SFP Fiber transceiver
must be in the closed (up) position before insertion.
2. When used in a standalone configuration, this product
must be used with a Listed Direct Plug-In Power Unit
marked “Class 2” and rated at 9VDC, 1 Amp.
Switch 1 Converter A
Converter B Switch 2
UTP Configuration DIP-Switches:
See the UTP Modes table on page 8.
LOOPBACK
LED On
LED Off
The auto-negotiation feature can be disabled on both ports
(for manual configuration) using DIP-switches on the
product. This is useful in a situation where the GX/T is
connected to a non-negotiating device and the configuration
parameters must be set manually.
The FlexPoint GX/T has the capability to provide loopback
to aid in installation and maintenance. A DIP-switch is
used to enable loopback on the module (see page 7).
Figure 1 shows the module in normal and loopback modes.
Pause “On/Off” DIP-Switch:
LED Status depends on connected device
NOTE: If mounting with a safety ground attachment,
use the safety ground screw at the rear of the unit.
In auto-negotiation mode, setting this DIP-switch to “On”
allows the unit to advertise as Symmetrical and
Asymmetrical Pause capability. In auto-negotiation mode,
Figure 2: Link Modes
NOTE: Connecting two converters with both set to RFD
mode is not supported and will cause a “deadly embrace”
NOTE: Remove safety ground screw when installing
the module in the 14-Module Chassis or when using
lockup.
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
setting the DIP-switch to “Off” causes the unit to advertise
no Pause capability. In the manual mode, this DIP-
switch determines the Symmetrical Pause behavior.
UTP MODES
LED INDICATORS
cover by personnel not specifically authorized and certified
by Omnitron), or misuse, or operating outside the
environmental specification of the product (including but
not limited to voltage, ambient temperature, radiation,
unusual dust, etc.), or improper site preparation or
maintenance.
SPECIFICATIONS
Warning
SW3
SW4
SW5
SW6
UTP Mode of Operation
The operating description in this Instruction Manual is for
use by qualified personnel only. To avoid electrical shock,
do not perform any servicing of this unit other than that
contained in the operating instructions, unless you are
qualified and certified to do so by Omnitron Systems
Technology, Inc.
Model Type
GX/T
LED Function
"Legend"
On / Blinking State
Color
Off State
AN/MAN
10/100/
1000
10/100 FDx/HDx
IEEE 802.3
10BASE-T, 100BASE-TX, 1000BASE-T, 100BASE-FX,
1000BASE-X
Loopback “Off/On” DIP-Switch:
Setting this DIP-switch “On” enables loopback on the
fiber and UTP ports (see Figure 1).
Protocols
On: Module has power
Blinking: Module in loopback
Power / Test
"Power"
Green No power
AN
1000
NA
FDX
Configured for Auto Negotiation.
(1000F, 1000H, 100F, 100H, 10F,
10H)
mode
Frame Size
UTP Cable
10,240 byte max. frame size
RJ-45, Category 5 and higher
On: Fiber port configured for AN
Blinking: Fiber port configured for
AN but in manual mode
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
F/O AN
"F/O-Auto-Neg"
Port configured for
manual negotiation
Green
Green
Link Modes:
AN
AN
1000
10-100
10-100
10-100
10-100
1000
NA
100
100
10
HDX
FDX
HDX
FDX
HDX
FDX
Configured for Auto Negotiation.
(1000H, 100F, 100H, 10F, 10H)
See the following table for configuring link modes:
Caution
On: Fiber port linked at 100Mbps
Blinking (10Hz): Link activity at
100Mbps
Multimode: 50/125, 62.5/125, 100/140µm
Single-mode: 9/125µm
Configured for Auto Negotiation.
(100F, 100H, 10F, 10H)
Fiber Cables
SW9
SW10
Result
All user-required operations can be performed without
opening the unit. Never attempt to open or remove the
cover or tamper with the unit.
F/O Speed 100*
"F/O-100"
Not connected at
100Mbps
Exclusive Remedies
"LS/LP"
"RFD/Normal"
UTP Connectors
Fiber Connectors
RJ-45
AN
Configured for Auto Negotiation.
(100H, 10F, 10H)
Blinking (1Hz): Signal detected
but port unable to establish a link
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
LS
LP
Normal
Normal
Enables Link Segment mode (LS).
Enables Link Propagate mode (LP).
ST, SC, LC (SFP)
AN
Configured for Auto Negotiation.
(10F, 10H)
On: Fiber port linked at 1000Mbps
Blinking (10Hz): Link activity at
1000Mbps
Warranty
Fiber: Auto-Neg, 1000, 100
Enables Remote Fault Detection mode plus
Link Segment mode (RFD+LS).
DIP-Switches
LED Displays
UTP: Auto-Neg, 10, 100, 1000, FDX/HDX, Pause En/Dis
Loopback, Link Seg, Link Prop, Remote Fault Det.
LS
LP
RFD
RFD
AN
10
Configured for Auto Negotiation.
(10H)
This product is warranted to the original purchaser against
defects in material and workmanship for a period of TWO
YEARS from the date of shipment. ALIFETIME warranty may
be obtained by the original purchaser by REGISTERING this
product with Omnitron within 90 days from the date of shipment.
TO REGISTER, COMPLETE AND MAIL OR FAX THE
REGISTRATION PORTION OF THIS INSTRUCTION
MANUAL TO THE INDICATED ADDRESS. Or you may
register your product on the internet at
period, Omnitron will, at its option, repair or replace a product
which is proven to be defective.
F/O Speed 1000
"F/O-1000"
Not connected at
1000Mbps
Green
Blinking (1Hz): Signal detected
but port unable to establish a link
Pattern Blinking: AN remote Fault
bit detected
Enables Remote Fault Detection mode plus
Link Propagation mode (RFD+LP).
MAN
NA
Configured for Auto Negotiation.
(1000F)
Power, Fiber AN, Fiber Speed/Activity, UTP Speed/Activity,
Full/Half-Duplex
NOTE: RFD is only available when the fiber port is
operating in manual mode.
When the port is set to 1000, it is
always in AN mode.
UTP Duplex
"UTP-FDX"
Dimensions
Weight
W: 3.0" x D: 4.0" x H: 1.0"
6 oz. (without power adapter)
UL, CE, FCC Class A
Green Half-Duplex
On: UTP port in Full-Duplex
TECHNICAL SUPPORT:
For help with this product, contact our Tech. Support:
On: UTP port configured for AN
Blinking: UTP port configured for
AN but in manual mode
MAN
1000
NA
HDX
Configured for Auto Negotiation.
(1000H)
UTP AN
"UTP-Auto-Neg"
Port configured for
manual negotiation
Green
Green
REMOTE FAULT
Compliance**
When the port is set to 1000, it is
always in AN mode.
Phone:
Fax:
(949) 250-6510
(949) 250-6514
Each port will generate an “IEEE remote_fault indicator”
when the incoming signal to the port is lost. When a port
is configured for auto-negotiation, it will set the remote
fault bit “high” in the AN advertisement when the port
detects a loss of incoming signal. See LED Indicators
table on page 9 for specifics on how the unit reports the
detection of this signal.
UTP Speed 100
"UTP-100"
Not connected at
100Mbps
On: UTP port linked at 100Mbps
Blinking (10Hz): Link activity
Barrel
Connector
Molex
Connector
MAN
MAN
MAN
MAN
10-100
10-100
10-100
10-100
100
100
10
FDX
HDX
FDX
HDX
Port forced to 100 FDX
Port forced to 100 HDX
Port forced to 10 FDX
Port forced to 10 HDX
Power
Requirements
Nominal Voltage:
Voltage Range: 5.0 to 32.0VDC
9VDC
5VDC
On: UTP port linked at 1000Mbps
Blinking (10Hz): Link activity
UTP Speed 1000
"UTP-1000"
Not connected at
1000Mbps
Address: Omnitron Systems Technology, Inc.
140 Technology Drive, #500
5.0 to 32.0VDC
0.5A @ 5VDC
0.75A @ 5VDC
Green
Green
Nominal Power:
Maximum Power:
0.3A @ 9VDC
1A @ 9VDC
10
On: UTP port linked at 10Mbps
Blinking (10Hz): Link activity
For warranty service, the product must be sent to an Omnitron
designated facility, at Buyer’s expense. Omnitron will pay the
shipping charge to return the product to Buyer’s designated
US address using Omnitron’s standard shipping method.
UTP Speed 10
"UTP-100"
+
Temperature
Humidity
Altitude
0 to 50o
C
When the module is configured for auto-negotiation, the module will advertise in
the order shown in the parenthesis.
Not connected at
10Mbps
Irvine, CA 92618 USA
Pattern Blinking: (1Hz): Detecting
"remote_fault" (AN) on UTP port
5 to 95% (non-condensing)
-100m to 4000m
"UTP-1000"
E-mail:
URL:
When the fiber port is operating in 100BASE-FX, a loss of
incoming signal will cause the port to generate a Far-End-
Fault indicator pattern. See LED Indicators table on page
9 for specifics on how the unit reports the detection of
this signal.
"UTP Auto-Neg"
+
Limitation of Warranty
Blinking (1Hz): Unable to establish
AN link on the UTP port
Module without Power Adapter: 900,000
Module with Power Adapter -1: 250,000
Module with Power Adapter -2: 100,000
"UTP-100"
+
Green
-
MTBF (Hours)
The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance of
the equipment by Buyer, Buyer-supplied equipment, Buyer-
supplied interfacing, unauthorized modifications or
tampering with equipment (including removal of equipment
"UTP-1000"
*SFP models only
Form: 040-04700-001A 8/08
Page 9
Page 7
Page 8
Page 10
Page 11
Page 12
|