Omnitron Systems Technology Network Card 400FTD User Manual

12  
Omnitron Systems Technology, Inc.  
SPECIFICATIONS  
n
n
n
n
Protocol:  
IBM 5250 and 5250 Express for systems AS/400 and  
Systems 34/36/38  
3179, 3180, 3196, 3197, 3476, 3477, 5250, 5251,  
5291, 5292, and compatibles  
3262, 3812, 4214, 4224, 4234, 5219, 5224, 5225,  
5226, 5262, and compatibles  
Terminals:  
Printer’s Supported:  
Cable Types:  
Fiber Optic:  
Multi-mode glass fiber of sizes 50/125, 62.5/125, or  
100/140 micron  
STP:  
Twinax female to DB-9 female  
3 ft.  
6 ft.  
OST# 310-00012-000  
OST# 310-00013-000  
DB-15 female to DB-9 female  
3 ft.  
6 ft.  
OST# 310-00014-000  
OST# 310-00015-000  
UTP:  
Level 3 (EIA/TIA 568):  
24 AWG solid copper 100 +/- 15 Ohms @ 1.0 Mhz;  
7db per 1,000 ft. @ 1.0 Mhz (lower grade wiring at  
shorter distances)  
OmniRepeaterTM 400FTD  
n
n
Data Rate:  
1 Mbps +4%, -2%  
Supported Distances:  
Multi-mode fiber:  
Singlemode fiber:  
Port STP:  
15,000 ft.  
30,000 ft.  
5,000 ft.  
3,000 ft.  
Systems AS400/3X  
Port UTP:  
n
Indicators:  
Fiber to Desk Repeater  
Power:  
Test Mode:  
Green LED  
Red LED  
Link:  
Port:  
Physical Dimensions:  
Weight:  
Green-Red LED  
Green-Red LED  
W:3.46”xD:2.83”xH:0.78”  
2 lbs.  
n
n
n
n
User’s Manual  
Power Supply (External):  
Temperature:  
Operating:  
9 VDC @ 1.2A  
0° to 40°C  
Storage:  
-40° to 75°C  
Humidity:  
Up to 90% (non-condensing)  
TECHNICAL SUPPORT  
For assistance in installing this product, contact Omnitron’s Technical Support  
Department.  
Phone:  
Fax:  
(949) 250-6510  
(949) 250-6514  
Address:  
Omnitron Systems Technology, Inc.  
27 Mauchly #201  
Irvine, CA 92618, USA  
Email:  
URL:  
27 Mauchly #201, Irvine, CA 92618; (949) 250-6510, Fax: (949) 250-6514  
Document #040-02900-001  
 
10  
Omnitron Systems Technology, Inc.  
OmniRepeaterTM 400FTD  
Systems AS400/3X  
Fiber to Desk Repeater  
User’s Manual  
GENERAL DESCRIPTION  
The OmniRepeater 400FTD is a fourth generation IBM 5250 compatible active  
repeater. The OmniRepeater 400FTD provides fiber-to-the-desktop, extending the  
applicability of the 5250 protocol. Four models offer a selection of fiber (single or  
multimode) and power supply (110 or 220 Volt) type. The following models are  
discussed in this manual:  
STANDARD DESCRIPTION  
2900-UDF1 Multi-mode fiber, 110 Volt power supply  
2900-UDF2 Multi-mode fiber, 220 Volt power supply  
2910-UDF1 Singlemode fiber, 110 Volt power supply  
2910-UDF2 Singlemode fiber, 220 Volt power supply  
The OmniRepeater 400FTD is capable of reliably locking and maintaining  
synchronization with data rate variations of -2% to +4%. It features a Digital Phase  
Locked Architecture which facilitates reliable operation with a high noise immunity.  
It allows the OmniRepeater 400FTD to reliably synchronize and lock to legitimate  
data frames and also to discriminate and ignore any open, shorted or noisy inputs  
(induced or crosstalk). This makes the OmniRepeater 400FTD a reliable solution  
in environments where high availability, stability, reliability and low maintenance  
are important.  
OPERATION  
Switches & Indicators  
The OmniRepeater 400FTD has two switches. The switch on the left, switch 1,  
controls the polarity of the data. Switch 2 turns the fiber test mode on and off.  
1 2  
 
4
Omnitron Systems Technology, Inc.  
Omnitron Systems Technology, Inc.  
9
Both switches are placed in the down position at the factory. The following table  
explains the switch settings.  
Fiber Optic Media Test - OmniRepeater 400FTD & Omnitron 5250 Fiber Device  
To test the integrity of fiber optic cables as well as the fiber receiver of any Omnitron  
5250 fiber device (such as the OmniStar 400, OmniMux 400, or OmniMux 400XL),  
connect the transmitter of the OmniRepeater 400FTD to the receiver of the other  
Omnitron 5250 fiber device. If the fiber is unbroken, the fiber link activity LED of  
the far-end Omnitron 5250 device will illuminate green. Test each cable of the  
fiber optic pair in this manner.  
FIBER TEST  
POLARITY  
Inverted  
SWITCH 1  
Down  
Up  
SWITCH 2  
Down  
Up  
MODE  
Turned Off  
Non-Inverted  
Turned On  
In addition to the two switches there are four LED indicators in a 2x2 cluster.  
Refer to the drawings below.  
TTxx  
Rx  
N o r m a l  
C o n t r o l  
P o l a r i t y  
e T s t  
F i b e r  
OmniMux 400XL  
FIBER  
Omnitron Systems Tech. Inc.  
UTP/STP  
OmniRepeater 400FTD  
5250 Fiber / Twinax Repeater  
NOTE: TURN OFF THE FIBER INSTALLATION TEST MODE TO RETURN TO  
NORMAL OPERATIONAL MODE.  
The meaning of the LEDs is shown on the cover of the OmniRepeater 400FTD  
and in the tables below.  
Self Test Mode  
ALL LEDs  
MEANING  
Red for 0.5 seconds, then  
Green for0.5 seconds  
Passed Self Test  
Failed Self Test, call Omnitron  
Tech Support @ 714-250-6510  
Any other behavior  
 
8
Omnitron Systems Technology, Inc.  
Omnitron Systems Technology, Inc.  
5
Normal Mode  
Loopback Fiber Optic Media Test - Via Patch Panel  
To test the ingrate of the fiber optic cables when fiber cables are already installed  
to a patch panel, use a short patch cord to loopback the fiber optic pair attached to  
the OmniRepeater 400FTD.  
TOP RIGHT  
GREEN  
MEANING  
TOP LEFT  
GREEN  
MEANING  
Good data received from  
copper port  
Good data received from  
fiber link  
Data parity error received  
on copper port  
Data parity error received  
on fiber link  
RED  
OFF  
RED  
OFF  
Tx  
Rx  
No data received on  
copper port  
No data received on fiber link  
BOTTOM LEFT  
GREEN  
MEANING  
BOTTOM RIGHT  
GREEN  
MEANING  
Fiber Installation Test Mode  
is ON  
Power is on  
Fiber Installation Test Mode  
is OFF  
OFF  
Power is off  
OFF  
DIAGNOSTIC FEATURES  
The OmniRepeater 400FTD diagnostic features make it easy to install and maintain.  
There are three levels of diagnostics: Self Test, Fiber Installation Test, and run-  
time activity and error monitoring.  
If the fiber optic cables are unbroken, the fiber link LED will illuminate green. As  
before, note that the fiber test mode LED will be red, and the Power LED will be green.  
Self Test  
The power-on self test ensures that the OmniRepeater 400FTD is fully operational.  
When power is applied to the unit, self testing occurs. At the end of the self test, all  
four LEDs will illuminate for half a second, then green for half a second. After that,  
the POWER LED will remain green providing a continuous indication that the  
external power supply is operational.  
NOTE: TURN OFF THE FIBER INSTALLATION TEST MODE TO RETURN TO  
NORMAL OPERATIONAL MODE.  
Fiber Optic Media Test - 2 OmniRepeater 400FTD’s  
To test the integrity of fiber optic cables that are already installed, use two  
OmniRepeater 400FTD units connected to each other in TEST mode. If the fiber  
media is unbroken, the link LEDs on each unit will illuminate green.  
Fiber Installation Test  
The OmniRepeater 400FTD includes a built-in fiber installation tester. The fiber  
installation test mode may be activated by moving the TEST witch to the TEST  
position (up). This diagnostic feature provides the installer with a visual indication  
that the fiber optic cabling is intact and correctly installed. During the fiber test  
mode a valid frame is continuously transmitted over the fiber optic link. Any  
Omnitron 5250 fiber device (such as the OmniStar 400, the OmniMux 400, or the  
OmniMux 400XL) at the far end of the fiber optic cable will illuminate its fiber optic  
activity LED when the fiber optic cable is unbroken and the transmitting fiber is  
correctly connected at the far end device receive port.  
TTxx  
Tx  
Rx  
WARNING  
Rx  
During the fiber installation test mode, disconnect  
any UTP and STP connections to the host workstation  
controller to prevent controller conflicts.  
Again, note that the fiber test mode LED will be red and the Power LED will be green.  
Refer to FIBER INSTALLATION TEST CONFIGURATIONS for testing suggestions  
NOTE: TURN OFF THE FIBER INSTALLATION TEST MODE TO RETURN TO  
NORMAL OPERATIONAL MODE.  
 
6
Omnitron Systems Technology, Inc.  
Omnitron Systems Technology, Inc.  
7
Run-time Activity & Error Monitoring  
CONFIGURATION  
During normal operation the Link and Port LEDs provide continuous diagnostic  
information. These LEDs detect and display true link and port activity and data  
parity errors. This is accomplished by individual port monitoring and searching  
for legal frame header patterns.  
Normal  
a. Turn off the terminal or printer being attached.  
b. Attach the terminal or printer with the appropriate cable to the OmniRepeater  
400FTD.  
Upon detection of a valid frame pattern, a green LED indicator displays the  
detected activity. This feature assists in installation and in the selection of the  
correct polarity baluns and/or setting the polarity of the switch.  
c. Attach the fiber optic cables to the transmit and receive fiber optic connectors.  
d. Plug the external power supply into the appropriate AC wall outlet.  
e. Plug the power jack into the OmniRepeater 400FTD power connector.  
The data is analyzed for correct parity and the detection of parity error is  
indicated by a red LED. This feature facilitates the continuous monitoring of  
signal and line quality.  
f. The LEDs will all illuminate red then green to indicate that the self test is  
complete.The Power LED will remain green, while the Link and Port LED will  
reflect the current operational status.  
INSTALLATION  
Refer to the APPLICATIONS section for useful application information.  
Fiber Installation Test Configurations  
Unpacking  
a. Visual Inspection – Before unpacking, a visual inspection should be conducted  
in order to detect any physical damage to the equipment. Any evidence of the  
damage should be noted and reported immediately.  
The OmniRepeater 400FTD supports several test configurations.  
WARNING  
b. Unpacking – Place shipping container on a flat surface, cut straps or tape,  
open top. Take out each item carefully and place securely on a clean flat surface.  
Return all packing material into a container (foam, boxes, etc.), close and  
store away for future reuse.  
During all fiber installation test modes, disconnect  
any UTP and STP connections to the host workstation  
controller to prevent controller conflicts.  
c. Inspection – Inspect each item for any apparent damage, any evidence of  
damage should be noted and reported immediately.  
Loopback Fiber Optic Media Test - Via Patch Cable  
d. Content – Review the content; the following items should be included:  
To test the integrity of fiber optic media connect the fiber optic patch cable in a  
loopback fashion (i.e., one end in the transmit port and the other in the receive  
port). If the fiber is unbroken, the OmniRepeater 400FTD fiber link LED will illuminate  
green. If the fiber is partially or completely broken the LED will be red or off.  
(a) OmniRepeater 400FTD Unit  
(b) One (1) Power Supply Module  
(c) User Manual (this document)  
e. Please note any missing items or discrepancies and report them  
immediately.  
TTxx  
Rx  
SITE REQUIREMENTS  
Power  
A power outlet 115 Volts/60 Hz (230 Volts/50 Hz) should be available within 5 ft. of  
the unit.  
MODEL  
POWER OUTLET  
110 Volt - 60 Hz  
2900-UDF1  
Note that the fiber test LED will be red and the Power LED will be green.  
2900-UDF2  
2910-UDF1  
2910-UDF2  
220 Volt - 50 Hz  
110 Volt - 60 Hz  
220 Volt - 50 Hz  
 

Milwaukee Drill Hammer Drill User Manual
Multiquip Water Pump QP305SLT User Manual
NETGEAR Switch JGS500 User Manual
Nikon Scanner LS4000 User Manual
Nu Vu Food Saver AMP 12 User Manual
Omega Engineering Stud Sensor CDE681 User Manual
OPTI UPS Power Supply FS600 FS600B User Manual
Panasonic Air Conditioner CW A120VR User Manual
Panasonic Smoke Alarm 1568 User Manual
Paradyne Network Card JetFusion Integrated Access Device User Manual