Omega Vehicle Security Thermometer K 79 User Manual

K-79  
Dialtemp™ Thermometer  
INSTRUCTION  
SHEET  
M0299/0802  
SECTION 1 INTRODUCTION  
®
The OMEGA Model K-79 Series Pocket Thermometer is a small,  
mechanical (non-electronic) thermometer that is accurate, rugged and light  
in weight. The clear, easy to read 1" dial has a pointer that is directly driven  
by the sensitive bi-metal helix coil located in the shaft. The 0.142" diameter,  
5" stainless steel probe has a needle tip for penetrating semi-solid materials  
such as fruits and meats. The pointed probe is supplied with a tubular  
pocket case complete with a pocket clip and holder loop. (See Figure 1)  
LOOP HOLDER  
POCKET CLIP  
POCKET CASE  
DIALTEMP  
Figure 1 K-79 Thermometer with Pocket Case  
 
slowly and carefully to avoid bending. Do not hold the head when  
inserting, always hold the stem.  
CAUTION  
Do not place a "Dial Temp" thermometer in contact with a  
material where electrical voltage potential is present.  
SECTION 4 CALIBRATION  
OMEGA K-79 Series Pocket Thermometers are factory calibrated. The  
alloys used in the bi-metal element determine the span calibration and  
are not adjustable. The dial head itself, however, can be reset. This is  
done at ambient temperature, where the pointer remains stable, and the  
dial is adjusted.  
To reset the dial:  
1. Determine the room temperature by using a reference thermometer  
of known accuracy.  
2. Firmly hold the hex nut at the base of the dial with a 7/16” wrench.  
3. With your other hand, firmly grip the perimeter of the dial. Slowly  
turn the dial head until the reading corresponds to room the  
temperature.  
SECTION 5 SPECIFICATIONS  
Accuracy:  
1% of scale  
Approx. Response Time  
in Water:  
4 seconds for one time constant*  
1" diameter (25 mm)  
Head:  
Dial:  
White background with crisp letters, marks  
and numbers  
Stem:  
.142 O.D., 5" long, pointed (3.6 mm x 127 mm)  
7/16" hex (11 mm)  
Reset Nut:  
Pocket Case:  
Weight:  
Stainless steel with clip and holder loop  
.65 ounces (18.5 g)  
* “Time Constant” is the time required to reach 63.2% of instantaneous  
temperature change.  
 
Servicing Europe:  
Benelux:  
Postbus 8034, 1180 LA Amstelveen, The Netherlands  
Tel: +31 (0)20 3472121  
FAX: +31 (0)20 6434643  
OMEGAnet® Online Service  
Internet e-mail  
Toll Free in Benelux: 0800 0993344  
Czech  
Rudé armády 1868, 733 01 Karviná 8  
Servicing North America:  
Republic:  
Tel: +420 (0)69 6311899  
Toll Free: 0800-1-66342  
FAX: +420 (0)69 6311114  
USA:  
ISO 9001 Certified  
One Omega Drive, Box 4047  
Stamford CT 06907-0047  
Tel: (203) 359-1660  
France:  
11, rue Jacques Cartier, 78280 Guyancourt, France  
Tel: +33 (0)1 61 37 29 00 FAX: +33 (0)1 30 57 54 27  
Toll Free in France: 0800 466 342  
FAX: (203) 359-7700  
Canada:  
976 Bergar  
Laval (Quebec) H7L 5A1  
Tel: (514) 856-6928  
Germany/  
Austria:  
Daimlerstrasse 26, D-75392 Deckenpfronn, Germany  
FAX: (514) 856-6886  
Tel: +49 (0)7056 9398-0  
FAX: +49 (0)7056 9398-29  
Toll Free in Germany: 0800 639 7678  
For immediate technical or application assistance:  
®
United  
One Omega Drive, River Bend Technology Centre  
Northbank, Irlam, Manchester  
USA and  
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA  
Customer Service: 1-800-622-2378 / 1-800-622-BEST  
®
Kingdom:  
Canada:  
®
ISO 9002 Certified M44 5BD United Kingdom  
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN  
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA  
Tel: +44 (0)161 777 6611  
FAX: +44 (0)161 777 6622  
Toll Free in United Kingdom: 0800-488-488  
Mexico:  
En Espan˜ol: (001) 203-359-7803  
FAX: (001) 203-359-7807  
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its  
products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.  
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter  
specifications without notice.  
WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.  
WARRANTY/DISCLAIMER  
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from  
date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product  
warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each  
product.  
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an  
Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be  
defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the  
purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or  
unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of  
having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification;  
misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted,  
including but not limited to contact points, fuses, and triacs.  
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility  
for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with  
information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as  
specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND  
WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY  
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION  
OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this  
order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the  
purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential,  
incidental or special damages.  
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR  
21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s)  
be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes  
no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and  
hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.  
RETURN REQUESTS / INQUIRIES  
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY  
PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER  
SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the  
outside of the return package and on any correspondence.  
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.  
FOR WARRANTY RETURNS, please have the following informa-  
tion available BEFORE contacting OMEGA:  
1. Purchase Order number under which the product was  
PURCHASED,  
2. Model and serial number of the product under warranty, and  
FOR NON-WARRANTY REPAIRS, consult OMEGA for cur-  
rent repair charges. Have the following information avail-  
able BEFORE contacting OMEGA:  
1. Purchase Order number to cover the COST of the repair,  
2. Model and serial number of the product, and  
3. Repair instructions and/or specific problems relative to the  
product.  
3. Repair instructions and/or specific problems relative to  
the product.  
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in  
technology and engineering.  
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.  
© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or  
reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING,  
INC.  
M0299/0802  
 

Milan Technology Network Card MIL 185C User Manual
Multiquip High Chair WM45HCE User Manual
Musical Fidelity CD Player A55 User Manual
Nesco Oven 18 Qt User Manual
Netopia Network Router 3386 ENT User Manual
Oki All in One Printer B2500 Series User Manual
Omega Thermostat PRG101 User Manual
Omnimount TV Video Accessories Verona 37FP User Manual
Panasonic Battery Charger EY0L10 U1 User Manual
Panasonic Camera Flash DMW FL360 User Manual