LVR2 Series  
Specifications  
Sensing Length = __________ inches  
Resolution = 1Inch  
_____ Output: 4 to 20 mA, 2 wire Red(+) Black(-)  
Output: 4 mA with float at bottom  
Output: 20 mA with float at top  
_____ Output: Resistive, 220 per 1 Inch of indication  
_____ Output Resistive, Non Linear per application  
____ Output: 1 to 5 VDC, 3 wire  
Red(+) Black(-) White (output)  
Output: 1 V with float at bottom  
Output: 5 V with float at top  
Temperature range: -40˚C to 85˚C, -40˚C to 105˚C with Resistive Output  
Mounting: ___________________________  
General Information  
Cautions  
1. Continuous Level Sensors  
should be installed rigidly  
so the float is free to move  
as the liquid level changes.  
2. Continuous Level Sensors  
should be mounted in a tank  
area free of severe turbulence  
or protected from such  
1. The pressure, temperature and electrical limitations  
shown for the specified level sensor must not be exceeded.  
2. The pressures and temperatures must take into  
consideration possible surges in the temperature  
and pressure of the system.  
3. The liquids used must be compatible with the materials  
of construction. Specifications of materials will be given  
upon request.  
turbulence by appropriate and  
adequate slosh shields.  
4. Life expectancy of the sensor varies with applications.  
5. Ambient temperature changes can affect sensor set points,  
since specific gravities of liquids vary with temperature.  
Consult factory for assistance.  
6. Level sensors have been designed to be shock and  
vibration resistant. For maximum life, both should be  
minimized. Consult factory for assistance.  
7. Excessive contaminants in fluid may inhibit float operation  
and occasional wipe down may be necessary.  
8. Physical damage to product may render product unserviceable.  
9. Installation in a vessel made from magnetic materials may  
affect operation.  
3. Continuous Level Sensors  
stems should be vertical for  
best results, but satisfactory  
operation is possible in most  
liquids with the stem at up to a  
30˚ angle from vertical.  
4. Care should be taken that  
Continuous Level Sensors are  
always operated within  
electrical ratings.  
 

Miller Electric Welder TM 353E User Manual
MTD Trimmer Y26SS User Manual
Multiquip Portable Generator GAW 135H User Manual
Niles Audio Speaker RS8Si Coral User Manual
Nostalgia Electrics Fondue Maker CFF 980 User Manual
Nvidia Computer Hardware NVIDIA Quadro User Manual
Optimus Car Stereo System CD 8250 User Manual
Palsonic Stereo System PSML 926 User Manual
Panasonic Answering Machine KX TG5632M User Manual
Panasonic Impact Driver EY7546 User Manual