Lucent Technologies Marine Radio 1021OX User Manual

DEFINITY ONE™  
Communications System  
Release 2.0  
Installation Quick Reference  
555-233-738  
Comcode 108671546  
Issue 2  
June 2000  
 
Typical Bash (GAS) commands for installation  
Command  
Description  
alarmorig  
Turns on alarm origination from the GAM (INADS)  
alarmstat  
Gives global alarm status (major, minor, or none) for GAM,  
DEFINITY, and AUDIX  
cleargamalarm  
d1stat  
Clears alarms after analysis  
Displays the status of all application groups running on the  
system  
environment  
ftpserv  
Displays the TN795 temperature and voltage ranges  
Enables the ftp service  
gamalarmstat  
installconfig  
lucent help  
oss  
Displays GAM alarm information  
Installs license files (INADS)  
Lists all commands  
Sets telephone numbers for outgoing INADS calls  
pcAnywhere  
Starts the pcAnywhere application (use -c to stop applica-  
tion)  
reboot  
Reboots system as follows:  
nice: shuts down applications and Windows NT in a  
graceful manner  
immediate: reboots the system without waiting for the  
applications to shut down, causing possible loss of voice  
messages that are being recorded and all calls drop  
restartcause  
setip  
Displays the restart causes for system (for technician/  
TSC)  
Sets the IP address, subnet mask, and default gateway of  
the LAN interface to the customer’s LAN. Turns on RAS.  
Reboot is required.  
shutdown  
Shuts down:  
all: Lucent DEFINITY ONE applications  
system: all Lucent DEFINITY ONE applications and Win-  
dows NT  
appname: the name of the application to be shut down  
camp-on: (AUDIX feature) notifies users of a system shut-  
down all and waits for users to end their sessions before  
shutting down  
serialnumber  
Reads and displays the serial number of the circuit pack  
 
Physical Connection IP Address  
Local Monitor/Mouse/ 127.1  
Keyboard  
PCMCIA Network  
Connection  
192.11.13.6  
RAS Modem  
(Dial-up)  
10.21.0.X  
(X is Customer  
Dependent — Lucent  
Assigned)  
Customer’s LAN  
Customer Dependent  
(default login value of  
192.11.13.9)  
Once connected, there are several ways to access DEFINITY ONE, as shown in the  
next table.  
Access Method  
Telnet  
<ip addr> [Start > Run...]  
using appropriate ip-addrs  
http://<ip-addr>  
DSA  
Web Browser  
pcAnywhere  
using appropriate ip-addrs  
The following table shows Lucent Personnel Login information.  
Logins  
to Enter  
System  
Logins to  
Enter  
DEFINITY  
Logins to Enter  
AUDIX  
lucent1  
lucent2  
lucent3  
dinit  
atsc  
dinads  
dcraft  
acraft  
acraft  
Each row of logins has the same password. For example, the  
lucent1, dinit, and atsc logins all have the same password.  
The lucent logins are used for web browser and pcAnywhere access.  
All logins can be used for telnet access.  
The d and a logins (columns 2 and 3) are used for DSA access.  
 

Lanzar Car Audio Network Card OPTIX3B User Manual
LG Electronics Flat Panel Television 19LH20 User Manual
Link electronic Network Router 860 XL325V User Manual
Logitech Tablet Accessory MK605 User Manual
Mackie Musical Instrument U420 User Manual
Makita Battery Charger DC1804 MJ User Manual
Maytag Range 8113P644 60 User Manual
Memorex CD Player MPT 3460 User Manual
Memorex MP3 Player MPD8845 User Manual
Metra Electronics Switch 71 5520 User Manual