Lincoln Electric Welding Consumables 248 User Manual

US-CW338  
5/5/2008  
Date:  
MSDS No.:  
Outershield 81K2-H  
All  
Trade Name:  
Sizes:  
4/1/01  
Supersedes:  
M A T E R I A L S A F E T Y D A T A S H E E T  
For Welding Consumables and Related Products  
Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988  
SECTION I - IDENTIFICATION  
Manufacturer/  
Supplier:  
Product Type: Flux Cored Electrode  
The Lincoln Electric Company  
22801 St. Clair Avenue  
Cleveland, OH 44117-1199  
(216) 481-8100  
Classification: AWS E81T1-K2MH8  
SECTION II - HAZARDOUS MATERIAL (1)  
I M P O R T A N T !  
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal  
use of this product are covered by Section V; see it for industrial hygiene information.  
CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all sizes.  
(1) The term “hazardous” in “Hazardous Materials” should be interpreted as a term required and defined in the Hazards Communication  
Standard and does not necessarily imply the existence of any hazard. All materials are listed on the TSCA inventory.  
TLV  
PEL  
Ingredients:  
CAS No.  
13463-67-7  
7439-89-6  
7439-96-5  
7440-02-0  
7439-95-4  
1332-58-7  
7440-21-3  
7789-75-5  
11108-67-1  
Wt.%  
5
< 5  
< 5  
< 5  
mg/m3  
10  
mg/m3  
15  
Titanium dioxides  
Iron  
10*  
0.2  
1.5  
10*  
5 (c)  
1
Manganese and/or manganese alloys and compounds (as Mn)*****  
Nickel (metal)*****  
Magnesium and/or magnesium alloys and compounds (as Mg)  
Mineral silicates  
Silicon and/or silicon alloys and compounds (as Si)  
Fluorides (as F)  
Boron alloys (as B)  
0.5  
10*  
5**  
10*  
2.5  
10*  
5**  
10*  
2.5  
< 0.5  
< 0.5  
< 0.5  
< 0.5  
10*  
10*  
Carbon steel tube  
7439-89-6  
85  
10*  
10*  
Supplemental Information:  
(*)  
Not listed. Nuisance value maximum is 10 milligrams per cubic meter. (c)  
PEL value for iron oxide is 10 milligrams per cubic meter. TLV value  
for iron oxide is 5 milligrams per cubic meter.  
Value is for manganese fume. Present PEL is 5  
milligrams per cubic meter (ceiling value). Values  
proposed by OSHA in 1989 were 1.0 milligrams per  
cubic meter TWA and 3.0 milligrams per cubic meter  
STEL (Short Term Exposure Limit).  
(**)  
As respirable dust.  
(*****) Subject to the reporting requirements of Sections 311, 312, and 313 of  
the Emergency Planning and Community Right-to-Know Act of 1986  
and of 40CFR 370 and 372.  
SECTION III - HAZARD DATA  
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See Z49.1 referenced in Section VI.  
Product is inert, no special handling or spill procedures required. Not regulated by DOT.  
Rev 9/07  
(CONTINUED ON SIDE TWO)  
 

La Crosse Technology Weather Radio WS 9257U IT User Manual
Land Pride Lawn Mower DM3705 Series User Manual
Loewe Flat Panel Television 32HD DR+ User Manual
Lux Products Thermostat P521U User Manual
Lynx Network Router L 210 User Manual
Marantz Car Stereo System M CR610 User Manual
Maytag Dishwasher 6 915928 A User Manual
Melissa Coffeemaker 645 065 User Manual
Melissa Vacuum Cleaner 640 073 User Manual
Memorex DVD Player MVD2050 BLK User Manual