Lytecaster® Recessed Downlighting 1103R
®
Page 1 of 1
6 3/4 “ Aperture 0 Incandescent Non-IC Remodeler Frame-In Kit
Frame-in Kit
2
5
1
Top View
Ceiling Opening
7 1/8”
Reflector Trim
4
3
14 9/16”
Complete Fixture consists of Reflector Trim & Fram In Kit. Select each separately.
Frame-In Kit Reflector Trims — See Individual Reflector Trim Specification Sheets
Open Downlight
Open
Cross Basic
Enclosed Wall
Wet
Reflector Cone
Blade White
Baffles
Basic
Recessed Adjustable
Line Voltage
Diffusers Washer
Location
1143
1144
1112
1112NM
1132 1176WH 1105
1170M1
1121
1135
1184WH
1103R
1170M1 1105BNM 1171
1171
1124
1126
1135WH 1184CD
1185
1127
1127NM
1127BK
1129CL
1138
1144CD 1113
1105NM
1105WH
1176
1179M1
1179WH
1129CLNM 1138NM
1145
1146
1113WH
1113BK
1128
1186
1129GD
1148
1134
1186WH
1127BKNM 1129GDNM 1148NM
1127CDNM 1129BK
1146CD 1113BKNM
1177SH
1178SH
1190
1149
1113CD
1127CD
1129BKNM
1129WH
1150
1151
1113CDNM
1113NM
1127BNM
1127WH
1129
1151CD
Satin Cone
1108
1108NM
1110
1129NM
1129BKNM
Low Voltage
1110NM
1152
1155
1161
1161WH
1163
1164
1155WH
Eyeball
1122
1123
1182
1122WH
1123WH
Features
1. Mounting Ring: .032 (#22 ga.) galvanized steel. Accommodates existing
ceilings up to 2” thick. Attaches securely to any type of ceiling material
without tools using (3) mounting straps provided. Push-in/twist-out clips
hold reflector flush to ceiling. Includes adhesive backed aperture template.
2. Junction Box: 2 1/2” X 2 1/2” X 3 1/2” (21 cu. in.) .032 (#22 ga.) galvanized
steel. U.L.listed for 90° C supply wire. Integral cable clamps permit attach-
ment of non-metallic (#12 or #14 ga.) Romex® cable without tools or addi-
tional connectors. Attaches to mounting ring without tools.
Romex® is a registered trademark of General Cable Industries Inc.
US and Foreign Patents Pending.
Job Information
Type:
Job Name:
Cat. No.:
3. Socket Housing: Impact extruded aluminum or galvanized steel.
4. Socket: Porcelain medium base; nickel plated screw shell. Pre-wired with
#18 ga. SF1 (300 VOLT 200° C) leads to junction box.
5. Thermal Protector: Meets NEC and U.L. requirements. Do not install
insulation within 3 inches of fixture sides or wiring compartment nor above
fixture in such a manner as to entrap heat.
Lamp(s):
Notes:
Options & Accessories
Thermal Protector Replacement:
Replacement Clips (Set of 3):
1970
1997
Lightolier a Genlyte company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • F0906
Labels
UL (Suitable for Damp Locations)
|