La Crosse Technology Clock WS 9032U User Manual

WS-9032U  
Wireless 433 MHz  
Weather Station  
Instruction Manual  
FCC ID: OMO-01RX (Receiver), OMO-01TX (transmitter)  
FCC DISCLAIMER  
This device complies with part 15 of the FCC rules. Operation is subject to the  
following two conditions:  
R
(1) This device may not cause harmful interference.  
(2) This device must accept any interference received, including interference that  
may cause undesired operation.  
Contents  
Language  
English  
French  
Page  
2
23  
Spanish  
46  
 
3. Do not press any buttons for at least ten minutes. If a button is pressed before the  
indoor weather station has received information from the TX4U sensor, no data  
will be received from that sensor until reset.  
III. Explanation of LCD Information  
A. The below picture highlights the LCD features.  
4. Replace the battery cover.  
Radio-controlled  
II. Start Up Sequence  
A. Initial Start  
WWVB Reception  
Indicator  
1. Immediately after the batteries have been installed, the indoor weather station  
will sound a “beep”, and the LCD will completely light up for a brief moment.  
2. All information will then appear in normal mode, with “12:00” as the default time  
and “TH.1” as the default date (2004 as the year).  
3. The indoor temperature and humidity, and barometric air pressure (as 29.91 inHg  
relative RH) will also be displayed.  
Date Display  
Comfort Icon  
Moon Phase Display  
4. There is a “satellite” icon that appears in the bottom portion of the LCD, between  
the outdoor temperature and humidity - this icon informs the user that the indoor  
weather station is looking for signals from the remote thermo/hygro sensor. Within  
five minutes the remote temperature and humidity should be displayed-if not,  
remove batteries from all units and repeat battery installation, the remote tem-  
perature sensor first, then the indoor weather station.  
Indoor Temperature  
Humidity Display  
Forcast Icon  
Air Pressure  
Trend Indicator  
B. WWVB Reception  
1. Once the batteries are installed in the Weather Center, it will automatically search  
for the WWVB signal. If it receives a good signal (which is unlikely during daylight  
hours in most locations), the WWVB reception indicator (looks like a tower icon)  
will flash. The indoor weather station requires five full minutes of good reception  
to successfully capture the signal and set to the correct hour, minute, second,  
month, day and year. If the signal reception is not successful within ten minutes,  
the signal search will be cancelled and will automatically resume every two hours  
until the signal is successfully captured.  
Barometric Air  
Pressure  
24-hour Air  
Pressure History  
2. The signal is sent from Ft. Collins, Colorado only and is similar to an AM radio  
signal. Atmospheric interferences such as storms, sunspots, and even sunlight  
will cause the signal to not travel as far.  
3. To maximize reception, place the indoor weather station in a window facing  
Colorado, at least six feet from any electrical source (computers, televisions,  
refrigerators, etc.). Do not move the indoor weather station while it is searching  
for the signal.  
Outdoor Temperature  
Humidity Display  
4. The time and date can be manually set. Once the signal is captured, it will over-  
ride any time and date set to the time zone selected.  
5. Once the time and date are set, the indoor weather station will conduct a search  
every night at midnight and correct to the accurate time and date (Daylight Sav-  
ing Time is automatic). If the signal has been received in the past 24 hours, the  
reception indicator will be displayed.  
Remote Sensor Number  
(Up to 3 Total)  
B. There are many different modes the indoor weather station can be set to. The  
LCD shown is the normal operating mode, and your actual data shown will be  
different based on your local settings and conditions.  
GB P.6  
P.7 GB  
IV. Function Key Layout  
D. DST ON/OFF Setting  
A. The below picture shows the five function keys used in programming and opera-  
tion of your indoor weather station  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button twice more to advance to the DST ON/OFF  
setting.  
4. “DST” will appear to the right of the Moon Phase display and “ON” or “OFF” will  
flash above that.  
5. Press and release the “OUT/+” button to select DST ON/OFF.  
Note: Some locations (Arizona and parts of Indiana) do not follow Daylight Saving  
Time.  
V. Program Mode  
6. Press and release the “SET” button to confirm the DST ON/OFF setting and  
continue to the Radio-controlled Time ON/OFF setting.  
The program mode is laid out in a manner that allows you to program each function  
separately, or you can follow the instructions entirely to program the indoor weather  
center. Complete programming is usually done for the initial set-up, and will require  
you to skip step 1,2 and 3 of each programming section. The programming mode  
can be exited at any time by either pressing the “Snooze/CH” button, or waiting for  
the 15-second time-out to take effect.  
E. Radio-controlled Time ON/OFF Setting  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button three more times to advance to the Radio-  
controlled time ON/OFF setting.  
A. Overview of programming mode sequence  
4. “RCC” will appear to the right of the Moon Phase display and “ON” or “OFF” will  
flash above that.  
1. LCD Contrast  
2. Time Zone  
3. DST ON/OFF  
5. Press and release the “+” button to select Radio-controlled time ON/OFF setting.  
6. Press and release the “SET” button to confirm the Radio-controlled time ON/OFF  
setting and continue to the 12/24-hour Time Mode setting.  
4. Radio-controlled Time ON/OFF 5. 12/24-hour time mode 6. Hour  
7. Minute  
8. Year  
9. Month  
10.Date  
11.˚F/˚C  
12.inHg/hPa  
13.Relative pressure setting  
14.Forecast sensitivity  
F. 12/24-hour Time Mode  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button four more times to advance to the 12/24-hour  
time mode setting.  
4. “12h” or “24h” will flash to the right of the Moon Phase display.  
5. Press and release the “OUT/+” button to select 12 or 24-hour time mode.  
B. LCD Contrast Setting  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “OUT/+” button to select the desired LCD contrast setting.  
4. Press and release the “SET” button to confirm the LCD contrast setting and con-  
tinue to the Time Zone setting  
Note: In 12h mode “PM” will appear to the left of the time during PM hours. If the  
time is not within the PM hours nothing will be displayed. Be sure to set the time to  
the correct AM/PM time to ensure automatic reception.  
C. Time Zone Setting  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button once more to advance to the Time Zone  
setting.  
6. Press and release the “SET” button to confirm the 12/24-hour time mode setting  
and continue to the Hour setting  
4. A number will flash to the left of the letter “h” at the top of the display just below  
the time display.  
G. Setting The Hour Manually  
5. Press and release the “+” button to select the desired time zone.  
6. Press and release the “SET” button to confirm the Time Zone setting and con-  
tinue to the DST ON/OFF setting.  
The WWVB signal will override any manual set time and date information. The time  
will be based on the time zone selected.  
 
GB P.8  
P.9 GB  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button five more times to advance to the Manual  
Hour setting.  
5. Press and release the “OUT/+” button to select the desired date.  
6. Press and release the “SET” button to confirm the date and continue to the Tem-  
perature Measuring Units setting.  
4. The hour will begin to flash at the top of the display.  
5. Press and release the “OUT/+” button to select the desired hour.  
6. Press and release the “SET” button to confirm the hour setting and continue to  
the Minute setting.  
L. Temperature Measuring Units Selection (˚F or ˚C)  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button ten more times to advance to the Tempera-  
ture Measuring Units setting.  
H. Setting The Minutes Manually  
4. ˚F or ˚C will flash at the top of the display.  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button six more times to advance to the Manual  
Minutes setting.  
5. Press and release the “OUT/+” button to select the desired temperature measur-  
ing unit.  
6. Press and release the “SET” button to confirm the temperature measuring unit  
and continue to the Air Pressure Measuring Units setting.  
4. The minutes will begin to flash at the top of the display.  
5. Press and release the “OUT/+” button to select the desired minutes.  
6. Press and release the “SET” button to confirm the minutes and continue to the  
Year setting.  
M. Air Pressure Measuring Units Selection (inHg/hPa)  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button eleven more times to advance to the Air  
Pressure Measuring Units setting.  
I. Setting TheYear Manually  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button seven more times to advance to the Manual  
Year setting.  
4. The year will begin to flash to the right of the Moon Phase display.  
5. Press and release the “OUT/+” button to select the desired year.  
6. Press and release the “SET” button to confirm the year and continue to the Month  
setting.  
4. inHg or hPa will flash at the top of the display.  
5. Press and release the “OUT/+” button to select the desired air pressure measur-  
ing unit.  
6. Press and release the “SET” button to confirm the air pressure measuring unit  
and continue to the Relative Pressure setting.  
N. Relative Pressure Setting  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button twelve more times to advance to the Relative  
Pressure setting.  
4. The barometric air pressure will flash in the middle of the display, just below the  
forecast icon  
5. Press and release the “OUT/+” or “IN” button to select the desired air pressure  
measuring unit.  
6. Press and release the “SET” button to confirm the relative pressure setting and  
continue to the Forecast Sensitivity setting.  
J. Setting The Month Manually  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button eight more times to advance to the Manual  
Month setting.  
4. The Month will begin to flash to the right of the Moon Phase display.  
5. Press and release the “OUT/+” button to select the desired month.  
6. Press and release the “SET” button to confirm the month and continue to the  
Date setting.  
O. Forecast Sensitivity Setting  
K. Setting The Date Manually  
1. Press and hold the “SET” button for five seconds.  
1. Press and hold the “SET” button for five seconds.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button nine more times to advance to the Manual  
Date setting.  
2. “lcd” will appear at the top of the display and a number will flash next to it.  
3. Press and release the “SET” button thirteen more times to advance to the Fore-  
cast sensitivity setting.  
4. The two air pressure tendency arrows will begin flashing on either side of the  
forecast icon and a flashing number will appear under the forecast icon.  
4. The date will begin to flash to the right of the Moon Phase display.  
GB P.10  
P.11 GB  
5. Press and release the “OUT/+” button to select the desired forecast sensitivity  
setting.  
B. Moon Phase  
1. There are 12 moon phases shown on the indoor weather station; the black por-  
tion signifies the portion of the moon visible in the sky.Thus, when the moon icon  
is all black, it is a full moon. The indoor weather station is programmed with all  
moon phases from the year 2003 until 2029.  
Note: Barometric air pressure is usually reported as “relative air pressure”. This  
reading is based on the combination of absolute air pressure and altitude. In general,  
an increase in altitude will result in a decrease in air pressure. Relative air pressure  
will make readings in nearby locations relative to each other to allow for proper  
forecasting. The absolute air pressure reading in the Weather Center cannot be  
calibrated, only the relative air pressure.  
Waxing Crescent  
New Moon  
Waxing Gibbous  
First Quarter  
6. Press and release the “SET” button to confirm the forecast sensitivity setting.  
THE MANUAL SETTING IS NOW COMPLETED  
FEATURES AND OPERATIONS  
A. Time Alarm Setting and Operation  
1. To set the time alarm:  
a. Press and hold the ALM/DATE button for 5 seconds.  
b. The alarm time will begin to flash to the right of the moon phase.  
c. Press and release the IN button to adjust the hour.  
Full Moon  
Last Quarter  
Waning Gibbous  
Waning Crescent  
C. Minimum and Maximum Temperature and Humidity  
1. Indoor Minimum and Maximum Temperature and Humidity  
Note: When in the 12-hour mode and setting an alarm for a time between noon and  
midnight, “PM” will appear to the left of the alarm time.  
The indoor weather station automatically stores the minimum and maximum indoor  
temperature and humidity. The minimum and maximum values are updated auto-  
matically when a new minimum or maximum is recorded, or until manually reset.  
d. Press and release the OUT/+ button to adjust the minutes.  
e. Press and release either of the SNOOZE/CH buttons to confirm the setting or  
wait for 20 seconds and the display will automatically return to the normal mode.  
a. From the normal display mode, press and release the “IN” key once to view the  
indoor maximum temperature and humidity (“MAX” will be displayed above the  
indoor temperature and humidity).  
2. To activate the alarm:  
a. Press and release the ALM/DATE button to toggle between the alarm time and  
the day and date.  
b. When the alarm time and alarm icon are showing to the right of the moon phase  
the alarm is activated.  
b. Press and release the “IN” key again to view the indoor minimum temperature  
and humidity.  
c. Press and release the “IN” key again to return to the normal mode (timeout of  
viewing minimum/maximum values will occur if no keys are pressed for fifteen  
seconds).  
c. When the day and date are showing in the DATE LCD the alarm is deactivated.  
Note: To reset the indoor minimum and maximum temperature and humidity, first  
display the values you wish to reset (minimum or maximum). Next press and hold  
the “SET” key for at least three seconds. You will see then that the values will reset  
to the current temperature and humidity and corresponding time.  
3. To activate the snooze:  
a. While the alarm is sounding press and release the SNOOZE/CH button.  
b. The snooze will be activated for 10 minutes. The alarm will come back on after  
10 minutes.  
c. To deactivate the snooze function press and release any button other than either  
of the SNOOZE/CH buttons.  
2. Outdoor Minimum and Maximum Temperature and Humidity  
The indoor weather station automatically stores the minimum and maximum out-  
door temperature and humidity. The minimum and maximum values are updated  
automatically when a new minimum or maximum is recorded, or until manually reset.  
 
GB P.12  
P.13 GB  
a. From the normal display mode, press and release the “OUT/+” key once to view  
the outdoor maximum temperature and humidity (“MAX” will be displayed above  
the outdoor temperature and humidity).  
b. Press and release the “OUT/+” key again to view the outdoor minimum tempera-  
ture and humidity.  
Each remote sensor will have its own minimum and maximum values stored.  
E. Comfort Indicator for Indoor Temperature and Humidity  
1. The comfort level indicator appears inbetween the indoor tempearture and  
humidity.  
c. Press and release the “OUT/+” key again to return to the normal mode (timeout  
of viewing minimum/maximum values will occur if no keys are pressed for fifteen  
seconds).  
2. The indicator will display a “happy-face” when the temperature is between 68˚F  
and 79˚F (20˚C and 25.9˚C), and the humidity is between 45% and 64%.  
3. A “sad-face” will be displayed when the temperature and humidity are outside the  
mentioned ranges.  
d. Note: To reset the outdoor minimum and maximum temperature and humidity,  
first display the values you wish to reset (minimum or maximum). Next press and  
hold the “SET” key for at least three seconds. You will see then that the values  
will reset to the current temperature and humidity and corresponding time.  
F. Weather Forecast Icon and Pressure Trend Indicators  
The weather forecasting feature is estimated to be 75% accurate, and is based solely  
upon the change of air pressure over time. The WS-9032U averages past air-pres-  
sure readings to provide an accurate forecast-creating a necessity to disregard all  
weather forecasting for 12-24 hours after the unit has been set-up, reset, or moved  
from one altitude to another (i.e. from one floor of a building to another floor). In  
areas where the weather is not affected by the change of air pressure, this feature  
will be less accurate.  
D. Multiple Remote Temperature Sensors  
The WS-9032U is able to receive signals from 3 different remote sensors. These  
extra remote sensors can be purchased through the same dealer as this unit. A  
TX4U will monitor the temperature and humidity, a TX3U will monitor temperature  
and display the temperature on its LCD, a TX3UP will monitor the temperature via a  
probe for measuring soil or water temperatures and a TX6U will monitor the tem-  
perature only.  
1. Weather Icons  
a. There are 3 possible weather icons that will be displayed at various times in the  
center of the indoor weather station.  
Note: When setting up multiple units it is important to insert batteries first into all the  
remote sensors, and in numeric sequence. Second install batteries into the indoor  
weather station. Transmission problems will arise if this is not done correctly and if  
the total time for set-up exceeds 6 minutes  
1. Set Up of Multiple Units  
a. It is necessary to remove the batteries from all units currently in operation.  
b. Remove the battery covers to all remote sensors.  
c. Place all remote sensors in a numeric sequential order.  
d. In sequential order, install batteries following the same battery installation proce-  
dures seen in Detailed Set-Up Guide section of this manual.  
e. Install batteries into the indoor weather station.  
i
Sunny-indicates that the weather is expected to improve (not that the weather  
will be sunny).  
ii Sun with Clouds-indicates that the weather is expected to be fair (not that the  
weather will be sunny with clouds).  
iii Clouds with Rain-indicates that the weather is expected to get worse (not that  
the weather will be rainy).  
b. The weather icons change when the unit detects a change in air pressure.  
c. The icons change in order, from “sunny” to “sun with clouds” to “clouds with rain”  
or the reverse.  
f. Follow the Detailed Set-Up Guide for programming and operating instructions.  
2. Viewing and Operating with Multiple Remote Sensors  
a. To view the temperature of a different remote sensor press and release either of  
the “SNOOZE/CH” buttons. A shift from one “boxed” number to the next should  
be observed in the OUTDOOR LCD.  
d. It will not change from “sunny” directly to “clouds with rain”, although it is possible  
for the change to occur quickly.  
e. If the symbols do not change, the weather has not changed (or the change has  
been slow and gradual).  
b. The minimum and maximum temperature of the additional remote sensor can be  
displayed by pressing the “OUT/+” button.  
f. The sensitivity of the change in foreacst icon is set by the user in section F of the  
Detailed Set Up Guide.  
c. To reset the minimum and maximum temperature readings press and hold the  
“SET” button for 3 seconds and that temperature/humidity record for that remote  
sensor will be reset only.  
GB P.14  
P.15 GB  
G. Weather Tendency Arrows  
has a falling trend, and the weather should worsen.  
8. Multiply the two values to find past air pressure (note the + or - sign of values on  
the verticle axis); i.e. 0.03 hPa x 3 = 0.09 hPa, now add this value to the air  
pressure (in LCD 4) to evaluate what past air pressures have been.  
9. The bar chart will constantly scroll to avoid burnout of the LCD.  
Pressure trend arrow  
Note: This feature cannot be turned off.  
1. Along with the forecast icon there is a pressure tendency arrow.  
2. There is one that points up (on the left side of the LCD) and one that points down  
(on the right side of the LCD).  
3. These arrows reflect current changes in the air pressure.  
4. An arrow pointing up indicates that the air pressure is increasing and the weather  
is expected to improve or remain good.  
5. An arrow pointing down indicates that the air pressure is decreasing and the  
weather is expected to become worse or remain poor.  
6. No arrow means the pressure is stable.  
7. A storm can be expected if there is a drop of 4 hPa or more in less than 6 hours.  
The clouds with rain icon will be displayed and the tendency arrow that points  
down will be flashing-indicating the storm warning feature has been activated.  
The flashing will stop when the air pressure stabilizes or begins to rise.  
MOUNTING  
Note: Before permanently mounting, ensure that the indoor weather station is able  
to receive signals from the transmitters and WWVB signal at the desired location.To  
achieve a true temperature reading, avoid mounting the remote thermo/hygro sen-  
sor (or any sensor) where direct sunlight can reach the remote sensor. We recom-  
mend that you mount the remote sensor on a North-facing wall or under an eve. The  
sending range of the remote thermo/hygro sensor is 330-ft (100m) however obstacles  
such as walls, concrete, and large metal objects can reduce the range. Place all  
units in their desired location, and wait approximately 15 minutes before perma-  
nently mounting to ensure that there is proper reception. If the indoor weather sta-  
tion loses the signal from the remote sensor, it will display the last temperature read-  
ing for 15 minutes. After 15 minutes of not receiving any signals, the remote tem-  
perature will display “- -.-”.  
H. Barometric Air Pressure Reading  
1. The actual barometric air pressure is displayed directly under the weather fore-  
cast icon  
2. The relative air pressure is calibrated by the user through the programming mode.  
3. Please Follow the programming instructions in section F of the Detailed Set Up  
Guide to set this feature.  
A. Mounting the Remote Thermo/hygro Sensor  
The remote thermo/hygro sensor can be mounted with the use of screws or by using  
the adhesive tape.  
1. Mounting with screws  
a. Remove the mounting bracket/receptor from the packaging.  
b. Place the mounting bracket over the desired mounting surface.  
c. Through the 2 screw holes of the bracket, mark the mounting surface with a  
pencil.  
I. Air Pressure History Bar Chart  
1. The bar graph shows in hPa (Hekto Pascal) the recorded air pressure over the  
past 24-hours.  
2. The horizontal axis shows the hours at increments of -24 hours, -18 hours, -12  
hours, -9 hours, -6 hours, -3 hours, and 0 hours (current).  
3. The vertical axis is set by hPa: the “0” on this axis represents the current hPa,  
and + or - 1,3,5, or 7 shows (in hPa) how high or low the past air pressure was as  
compared to the current one.  
d. Where marked, start the screw holes using the provided screws.  
e. Remove screws from the mounting surface.  
f. Align the mounting bracket with the started screw holes.  
g. Screw mounting bracket onto the mounting surface. The screws should be flush  
with the bracket.  
4. The “0” on the vertical axis indicates the current air pressure value.  
5. The “0h” on the horizontal axis indicates the current hour, thus the current air  
pressure also.  
h. Fit the mounting post (on the back of the transmitter) into the receptor of the  
mounting bracket.  
6. Each bar on the bar graph represents a value of 0.03 hPa, and each bar also has  
a corresponding value on the verticle axis.  
7. Air pressure trends can be determined by simply glancing at the bar graph.  
a. If the bars are rising (higher on the right than the left) then the air pressure has  
a rising trend, and the weather should improve.  
b. If the bars are dropping (lower on the right than the left) then the air pressure  
REMOTE  
REMOTE  
THERMO-SENSOR  
THERMO-SENSOR  
433 MHz  
433 MHz  
 
GB P.16  
P.17 GB  
2. Mounting with Adhesive Tape  
D. Immediately remove all low powered batteries to avoid leakage and damage.  
E. Opening the casings invalidates the warranty. Do not try to repair the unit. Con-  
tact La Crosse Technology for repairs.  
a. With a nonabrasive solution, clean and dry the back of the mounting bracket and  
the mounting surface to ensure a secure hold. The mounting surface should be  
smooth and flat.  
b. Remove the protective strip from one side of the tape.  
c. Press firmly onto the designated area on the back of the mounting bracket.  
d. Remove the protective strip from the other side of the tape, and situate the mount-  
ing bracket.  
e. Firmly press the mounting bracket onto the mounting surface.  
f. Fit the mounting post into the receptor of the mounting bracket.  
TROUBLESHOOTING  
Problem:  
Solution:  
1) Set the LCD contrast to a higher level.  
2) Replace batteries.  
The LCD is faint.  
Problem:  
No outdoor temperature/humidity is displayed.  
B. Mounting the WS-9032U Indoor Weather Station  
Solution:  
The indoor weather station can be mounted in two ways; free standing or hanging on  
a wall.  
1) Remove all batteries, reinsert into the remote thermo/hygro sensor first, then into  
the indoor weather station.  
2) Place remote thermo/hygro sensor closer to the indoor weather station.  
3) Be sure all batteries are fresh.  
4) No other interfering sources are being used (such as computer monitors, TV  
sets, headphones, or speakers) in the vicinity. The signal travels in a straight line,  
an electrical source near that “line” may cause interference.  
Problem:  
Solution:  
Temperature, humidity, or air pressure is incorrect.  
1) Check/Replace batteries.  
2) If multiple remote sensors are in use, check location with corresponding “boxed  
numbers.”  
3) Move away from sources of heat/cold.  
4) Adjust relative air pressure to a value from a reliable source (TV radio, etc.).  
5) The indoor weather station and remote sensors are calibrated at the factory. If  
there is a consistent problem, please call La Crosse Technology.  
To have the indoor weather station free standing, simply unfold the stands on the  
back and set on a stable flat surface.  
To wall mount the indoor weather station;  
Problem:  
Solution:  
“- -” in humidity display.  
1. Ensure that the integrated stands are folded in.  
1) Humidity is below 1% or above 99%.  
2. Fix a screw (not included) into the desired wall, leaving approximately 3/16 of an  
inch (5mm) extended from the wall.  
2) TX3U or TX3UP is used for remote temperature.  
3. Place the indoor weather station onto the screw using the hanging hole on the  
backside.  
Problem:  
Solution:  
WWVB time and date will not set or update  
4. Gently pull the indoor weather station down to lock the screw into place.  
1) Wait until overnight for signal to be received  
2) Move indoor weather station away from sources of electricity  
3) Place indoor weather station in window facing Colorado  
4) The first reception is most difficult, as the indoor weather station needs five con-  
tinual minutes of clear signal reception. After the initial time/date set, the indoor  
weather station only requires one full minute of clear reception each night.  
MAINTENANCE AND CARE INSTRUCTIONS  
A. Extreme temperatures, vibration, and shock should be avoided to prevent dam-  
age to the units.  
B. Clean displays and units with a soft, damp cloth. Do not use solvents or scouring  
agents; they may mark the displays and casings.  
C. Do not submerge in water.  
GB P.18  
P.19 GB  
SPECIFICATIONS  
This limited warranty begins on the original date of purchase, is valid only on prod-  
ucts purchased and used in North America and only to the original purchaser of this  
product. To receive warranty service, the purchaser must contact La Crosse  
Technology, Ltd for problem determination and service procedures. Warranty ser-  
vice can only be performed by a La Crosse Technology, Ltd authorized service center.  
The original dated bill of sale must be presented upon request as proof of purchase  
to La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service  
center.  
Indoor weather station recommended  
operating temperature  
LCD contrast  
Temperature measuring range  
Indoor  
32˚F to 122˚F (0˚C to 50˚C)  
8 levels (0-7)  
14.2˚F to 139.8˚F with 0.2˚F resolution  
(-9.9˚C to 59.9˚C with 0.1˚C resolution)  
(“OFLdisplayed if outside this range)  
Outdoor  
-21.8˚F to 157.8˚F with 0.2˚F resolution  
(-29.9˚C to 69.9˚C with 0.1˚C resolution)  
(“OFLdisplayed if outside this range)  
La Crosse Technology, Ltd will repair or replace this product, at our option and at no  
charge as stipulated herein, with new or reconditioned parts or products if found to  
be defective during the limited warranty period specified above. All replaced parts  
and products become the property of La Crosse Technology, Ltd and must be re-  
turned to La Crosse Technology, Ltd. Replacement parts and products assume the  
remaining original warranty, or ninety (90) days, whichever is longer. La Crosse  
Technology, Ltd will pay all expenses for labor and materials for all repairs covered  
by this warranty. If necessary repairs are not covered by this warranty, or if a prod-  
uct is examined which is not in need or repair, you will be charged for the repairs or  
examination. The owner must pay any shipping charges incurred in getting your La  
Crosse Technology, Ltd product to a La Crosse Technology, Ltd authorized service  
center. La Crosse Technology, Ltd will pay reasonable return shipping charges to  
the owner of the product.  
Relative humidity range  
Indoor/Outdoor  
weather station  
1% to 99% with 1% resolution, indoor  
displays “—.-” if outside this range  
Air pressure  
Relative hPa (adjustable)  
Relative inHg (adjustable)  
Sensitivity setting hPa  
Air pressure history  
18, and -24 hours)  
Data checking intervals  
Indoor temperature  
Indoor humidity  
Outdoor temperature  
Outdoor humidity  
Transmitter reading update (within sensor)  
Outdoor temperature  
Outdoor humidity  
Transmission frequency  
Transmission range  
Power supply  
960 hPa to 1040 hPa  
28.35 inHg to 30.72 inHg  
2 hPa to 4 hPa  
For the past 24 hours (0, -3, -6, -9, -12, -  
Every 15 second  
Every 20 seconds  
Every 5 minutes  
Every 5 minutes  
Your La Crosse Technology, Ltd warranty covers all defects in material and work-  
manship with the following specified exceptions: (1) damage caused by accident,  
unreasonable use or neglect (including the lack of reasonable and necessary  
maintenance); (2) damage occurring during shipment (claims must be presented to  
the carrier); (3) damage to, or deterioration of, any accessory or decorative surface;  
(4) damage resulting from failure to follow instructions contained in your owner’s  
manual; (5) damage resulting from the performance of repairs or alterations by some-  
one other than an authorized La Crosse Technology, Ltd authorized service center;  
(6) units used for other than home use (7) applications and uses that this product  
was not intended or (8) the products inability to receive a signal due to any source of  
interference.. This warranty covers only actual defects within the product itself, and  
does not cover the cost of installation or removal from a fixed installation, normal set-  
up or adjustments, claims based on misrepresentation by the seller or performance  
variations resulting from installation-related circumstances.  
Every 1 minute  
Every 1 minute  
433.92 MHz  
330 feet (100m)  
Weather Center:  
3 x AA (IEC LR6) 1.5V batteries.  
2 x AA (IEC LR6) 1.5V batteries.  
Thermo Hygro Transmitter:  
Dimensions (H x W x D)  
Indoor weather station  
8.93 x 4.62 x 1.22 inches  
(227 x 117.4 x 31.2 mm)  
4.29 x 1.56 x 0.78 inches  
(110 x 40 x 20 mm)  
Remote thermo/hygro sensor  
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR  
INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES  
ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT.  
THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUB-  
LIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S  
REACH.  
WARRANTY INFORMATION  
La Crosse Technology, Ltd provides a 1-year limited warranty on this product against  
manufacturing defects in materials and workmanship.  
 
GB P.20  
P.21 GB  
WARRANTY INFORMATION  
La Crosse Technology, Ltd provides a 1-year limited warranty on this  
product against manufacturing defects in materials and workmanship.  
This limited warranty begins on the original date of purchase, is valid  
only on products purchased and used in North America and only to  
the original purchaser of this product. To receive warranty service,  
the purchaser must contact La Crosse Technology, Ltd for problem  
determination and service procedures. Warranty service can only be  
performed by a La Crosse Technology, Ltd authorized service center.  
The original dated bill of sale must be presented upon request as  
proof of purchase to La Crosse Technology, Ltd or La Crosse  
Technology, Ltd’s authorized service center.  
La Crosse Technology, Ltd will repair or replace this product, at our  
option and at no charge as stipulated herein, with new or  
reconditioned parts or products if found to be defective during the  
limited warranty period specified above. All replaced parts and  
products become the property of La Crosse Technology, Ltd and  
must be returned to La Crosse Technology, Ltd. Replacement parts  
and products assume the remaining original warranty, or ninety (90)  
days, whichever is longer. La Crosse Technology, Ltd will pay all  
expenses for labor and materials for all repairs covered by this  
warranty. If necessary repairs are not covered by this warranty, or if  
a product is examined which is not in need or repair, you will be  
charged for the repairs or examination. The owner must pay any  
shipping charges incurred in getting your La Crosse Technology, Ltd  
product to a La Crosse Technology, Ltd authorized service center.  
La Crosse Technology, Ltd will pay ground return shipping charges to  
the owner of the product to a USA address only.  
Your La Crosse Technology, Ltd warranty covers all defects in  
material and workmanship with the following specified exceptions: (1)  
damage caused by accident, unreasonable use or neglect (including  
the lack of reasonable and necessary maintenance); (2) damage  
occurring during shipment (claims must be presented to the carrier);  
(3) damage to, or deterioration of, any accessory or decorative  
surface; (4) damage resulting from failure to follow instructions  
contained in your owner’s manual; (5) damage resulting from the  
performance of repairs or alterations by someone other than an  
authorized La Crosse Technology, Ltd authorized service center; (6)  
units used for other than home use (7) applications and uses that this  
product was not intended or (8) the products inability to receive a  
signal due to any source of interference.. This warranty covers only  
actual defects within the product itself, and does not cover the cost of  
installation or removal from a fixed installation, normal set-up or  
1
 
adjustments, claims based on misrepresentation by the seller or  
performance variations resulting from installation-related  
circumstances.  
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY  
FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER  
SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR  
MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO  
BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC  
INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF  
CHILDREN’S REACH.  
This warranty gives you specific legal rights. You may also have  
other rights specific to your State. Some States do no allow the  
exclusion of consequential or incidental damages therefore the above  
exclusion of limitation may not apply to you.  
For warranty work, technical support, or information contact:  
La Crosse Technology, Ltd  
2809 Losey Blvd S.  
La Crosse, WI 54601  
Phone: 608.782.1610  
Fax: 608.796.1020  
e-mail:  
(warranty work)  
(information on other products)  
web:  
2
 
FCC DISCLAIMER  
This device complies with part 15 of the FCC rules. Operation is  
subject to the following two conditions:  
(1) This device may not cause harmful interference.  
(2) This device must accept any interference received,  
including interference that may cause undesired  
operation.  
La Crosse Technology  
Made in China  
All rights reserved. This handbook must not be reproduced in any  
form, even in excerpts, or duplicated or processed using electronic,  
mechanical or chemical procedures without written permission of the  
publisher.  
This handbook may contain mistakes and printing errors. The  
information in this handbook is regularly checked and corrections  
made in the next issue. We accept no liability for technical mistakes  
or printing errors, or their consequences.  
All trademarks and patents are acknowledged.  
3
 

Land Pride Child Tracker 701 053a User Manual
Lasko Fan T38300 User Manual
Lenovo Computer Drive 43N3224 User Manual
Lexicon Stereo Amplifier RX 7 User Manual
LG Electronics Clothes Dryer DLEX3370R User Manual
Magnavox DVD Recorder MRV660 User Manual
Makita Drill NHPL030 User Manual
Makita Saw 5477NB R User Manual
Market Forge Industries Cookware ST 3E User Manual
Marshall electronic Camcorder V ZCAM4 User Manual