Klaxon Network Router CMC4 MMI User Manual

Electronic Siren Control Methods  
CMC4 MMI  
The CMC4 MMI unit provides a means of siren control and  
interrogation for a single siren system.  
Control of up to 4 alarm signals & 4 pre-recorded messages.  
Microphone input connector for live voice messages.  
Silent test activation facility and test results displayed  
on the 2 line LCD.  
Communication link to the siren is via an RS485 interface.  
Power for the unit is provided by the RS485 interface.  
Key operated switch to disable signal & voice activation  
function.  
CMC500 MMI  
The CMC500 MMI unit provides a means of control and  
interrogation required for a multiple siren system.  
Control of up to 16 alarm signals & 230 pre-recorded messages.  
Microphone input connector for live voice messages.  
LED display unit.  
User controllable alarm signal & message volume control.  
User controllable alarm signal & message repetition rate  
control.  
User controllable siren group control.  
Siren silent test activation facility and test results displayed  
on the 2 line LCD.  
Communication link to the siren is via an RS485 interface.  
Power for the unit is provided by an integral re-chargeable  
battery pack.  
Multi-user identification & control restriction function  
Talos 20 Software MMI Console  
The software which operates under Microsoft windows allows the  
means of control and interrogation required for a multiple siren  
system.  
Control of up to 16 alarm signals & 230 pre-recorded messages.  
Live voice control facility.  
Siren silent test activation facility and test results displayed.  
User definable legends.  
Master volume control.  
User definable siren group allocation.  
Event & test logs.  
Klaxon Signals Limited  
Wrigley Street, Oldham  
Lancashire, UK OL4 1HW  
T. +44 (0)161 287 5555  
F. +44 (0)161 287 5511  
 
Electronic Siren Control Methods  
Control Methods  
The siren control communication network can be implemented using any one of the following systems or with a  
combination of two of these systems.  
Land Mobile Narrow Band FM Radio. Operating frequencies VHF 136 - 174 MHz or UHF 403-470 MHz. Data and voice.  
TETRA. Data and voice.  
APCO - 25 (For use in the USA)  
2.4 & 5.8 GHz spread spectrum frequency hopping microwave radio data and voice.  
Single or bidirectional COFDM radio. Data and voice.  
Direct satellite - bidirectional data and voice.  
GSM and GPRS. Data. Voice subject to local service provider.  
Serial data and voice over 600 ohm lines (POT).  
RS-485 data.  
Fibre optic networks. Data and voice.  
TCP/IP. Data and VoIP.  
Serial data from SCADA terminal with standard DCS protocols.  
Parallel dry contact from SCADA or dedicated cables.  
Simple siren control by hardwire parallel inputs & control out puts.  
4 Control  
CS  
Relay outputs for  
8 Parallel  
Connection with  
Inputs for  
Existing systems  
Siren  
Connection  
Control  
AC Power  
Klaxon Signals Limited  
Wrigley Street, Oldham  
Lancashire, UK OL4 1HW  
T. +44 (0)161 287 5555  
 
F. +44 (0)161 287 5511 w. www.klaxonsignals.com  
Electronic Siren Control Methods  
Siren System by remote control by CMC-4.  
CMC - 4  
RX DATA  
TX DATA  
PTT  
TEST  
READ  
Sig  
1
Sig  
2
2
Sig  
3
Sig  
4
Msg  
1
Msg  
LIVE  
STOP  
Operation Panel CMC-4  
CS  
Microphon  
Siren  
Control  
Line  
Siren System remote control by RS485 and computer.  
CS  
Talos20  
Line RS485  
Software  
Siren  
Application  
Control  
Line  
Amplifier  
Microphone  
Klaxon Signals Limited  
Wrigley Street, Oldham  
Lancashire, UK OL4 1HW  
T. +44 (0)161 287 5555  
 
F. +44 (0)161 287 5511 w. www.klaxonsignals.com  
Electronic Siren Control Methods  
Siren System remote control by radio and CMC-4.  
Antenna  
Antenna  
SBD - VHF or SBD - UHF  
AC Power  
CMC - 4  
Base Station 19” 2U Rack  
RX DATA  
TX DATA  
PTT  
TEST  
READ  
Sig  
1
Sig  
2
2
Sig  
3
Sig  
4
CS  
Msg  
1
Msg  
LIVE  
STOP  
Operation Panel CMC-4  
Siren  
12VDC  
12AH - 44AH  
Microphon  
Control  
Battery  
Siren System remote control by radio and computer.  
Antenna  
Antenna  
SBD - VHF or SBD - UHF  
AC Power  
Base Station 19” 2U Rack  
CS  
Talos20  
Siren  
12VDC  
Software  
12AH - 44AH  
Application  
Control  
Battery  
Line  
Amplifier  
Microphone  
Klaxon Signals Limited  
Wrigley Street, Oldham  
Lancashire, UK OL4 1HW  
T. +44 (0)161 287 5555  
 
F. +44 (0)161 287 5511 w. www.klaxonsignals.com  
Electronic Siren Control Methods  
Multi siren system remote controlled by radio and computer.  
Wireless  
Network  
Antenna  
Antenna  
CS  
Siren  
// 1  
CS  
Siren  
// 2  
Antenna  
CS  
Antenna  
CS  
Siren  
// X  
Siren  
Talos20  
// 3  
Software  
Application  
Antenna  
SBD-VHF or S BD-  
RS 232  
AC Power  
Battery  
UHF  
12VDC  
Base Station 19” 2U  
Rack  
12AH - 44AH  
Desktop  
Microphone  
Multi siren system remote controlled by satellite network and computer.  
Satellite  
Network  
Satellite  
Antenna  
Satellite  
Antenna  
CS  
Siren  
// 1  
CS  
Siren  
// 2  
Satellite  
Antenna  
Satellite  
Antenna  
CS  
Siren  
// 3  
CS  
Siren  
// X  
Talos20  
Software  
Application  
Satellite  
Antenna  
Sat Phone  
Up -  
Ethernet  
downlink  
Desktop  
Microphone  
Klaxon Signals Limited  
Wrigley Street, Oldham  
Lancashire, UK OL4 1HW  
T. +44 (0)161 287 5555  
 
F. +44 (0)161 287 5511 w. www.klaxonsignals.com  

IOGear Bluetooth Headset GBE211 User Manual
Jenn Air Gas Grill 209240 User Manual
Jenn Air Oven JGW8130 User Manual
JVC CD Player KD G331 User Manual
Kambrook Clock Radio KCR40 User Manual
Kenmore Water Heater 153332318 User Manual
Kenwood Coffeemaker ES020 User Manual
Kenwood Two Way Radio KCT 22 User Manual
KitchenAid Blender 4KFPW760OB0 User Manual
KitchenAid Oven KEBS207SSS03 User Manual