Intex Recreation Water Pump 634 User Manual

(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
IMPORTANT  
SAFETY RULES  
Read, Understand, and Follow all  
Instructions Carefully before  
Installing and using this Product.  
Krystal Clear™  
Model 634 Filter Pump  
220 - 240 V~, 50 Hz, 360 W  
Hmax 1.5 m, H min 0.19 m, IPX4  
Max. Water Temperature 35 °C  
For illustrative purposes only.  
Don’t forget to try these other fine Intex products: Pools, Pool Accessories,  
Inflatable Pools and In-Home Toys, Airbeds and Boats available at fine  
retailers or visit our website.  
©2006 Intex Marketing Ltd. - Intex Development Co. Ltd. - Intex Recreation Corp.  
All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle  
Rechte vorbehalten.  
Printed in China/Imprimé en Chine/Impreso en China/Gedruckt in China.  
®™ Trademarks used in some countries of the world under license from/®™ Marques utilisées dans certains pays sous  
licence de/Marcas registradas utilizadas en algunos países del mundo bajo licencia de/Warenzeichen verwendet in einigen  
Ländern der Welt in Lizenz von/Intex Marketing Ltd. to/à/a/an Intex Development Co. Ltd., 8th Floor, Dah Sing  
Financial Centre, 108 Gloucester Road, Wanchai, Hong Kong & Intex Recreation Corp., P.O. Box 1440, Long Beach,  
CA 90801 • Distributed in the European Union by/Distribué dans l’Union Européenne par/Distribuido en la unión Europea  
por/Vertrieb in der Europäischen Union durch/Intex Trading B.V., P.O. Box nr. 1075 – 4700 BB Roosendaal – The  
Netherlands  
110**-A0-0701  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
IMPORTANT SAFETY RULES  
Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.  
READ AND FOLLOW ALL INSTRUCTIONS  
WARNING  
To reduce the risk of injury, do not permit children to use this product. Always  
supervise children and those with disabilities.  
Risk of electric shock. Connect this product only to a grounding type receptacle  
protected by a ground-fault circuit interrupter (GFCI) or residual current device  
(RCD). Contact a qualified electrician if you cannot verify that the receptacle is  
protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD,  
which has a maximum rate of 30mA. Do not use a portable residual current device  
(PRCD).  
Do not bury electrical cord. Locate cord where it will not be damaged by lawn  
mowers, hedge trimmers, and other equipment.  
If the supply cord is damaged, it must be replaced by the manufacturer, its service  
agent or similarly qualified persons in order to avoid a hazard.  
To reduce the risk of electric shock, do not use extension cords, timers, plug  
adaptors or converter plugs to connect unit to electric supply; provide a properly  
located outlet.  
Assembly and disassembly by adults only.  
Do not attempt to plug in or unplug this product while standing in water or when  
your hands are wet.  
• Position this product away from pool to prevent a child from climbing on pump to  
access the pool.  
Children must stay away from this product and electrical cord(s).  
Do not operate this product when pool is occupied.  
Always unplug this product from the electrical outlet before removing, cleaning,  
servicing or making any adjustment to the product.  
This product is for use with storable pools only. Do not use with permanently  
installed pools. A storable pool is constructed so that it may be readily  
disassembled for storage and reassembled to its original configuration.  
• Keep this product more than 2m away from the pool.  
• Keep this product more than 3.5m away from the pool (for France only).  
• Keep the plug of this product more than 3.5m away from the pool.  
• The plug shall be accessible after product installed.  
• This product is intended to be used only for the purposes described in the manual!  
FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN  
PROPERTY DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR  
OTHER SERIOUS INJURY OR DEATH.  
These product warnings, instructions and safety rules provided with the product represent  
some common risks of water recreation devices and do not cover all instances of risk and  
danger. Please use common sense and good judgement when enjoying any water activity.  
Page 3  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
PARTS LIST  
1
2
5
8
3
4
6
9
7
10  
11  
14  
12  
15  
13  
16  
NOTE: Drawings for illustration purpose only. May not reflect actual product. Not to scale.  
SAVE THESE INSTRUCTIONS  
Page 4  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
PARTS REFERENCE  
Before assembling your product, please take a few minutes to check the contents  
and become familiar with all the parts.  
1
2
3
4
5
6
7
8
3
2
NOTE: Drawings for illustration purpose only. May not reflect actual product. Not to scale.  
DESCRIPTION  
THREADED FILTER HOUSING COLLAR  
AIR RELEASE VALVE/SEDIMENT RELEASE VALVE  
VALVE O-RING  
REF. NO.  
QTY. SPARE PART NO.  
1
2
3
4
5
6
7
8
1
2
2
1
1
1
1
2
10491  
10460  
10264  
10490  
10492  
FILTER HOUSING COVER  
FILTER HOUSING O-RING  
FILTER CARTRIDGE (59905)  
AIR RELEASE VALVE B (WITH O-RING)  
PUMP HOSE WITH NUTS  
10725  
10494  
When ordering parts, be sure to quote the model number and part numbers.  
Page 5  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
PARTS REFERENCE (continued)  
Before assembling your product, please take a few minutes to check the contents  
and become familiar with all the parts.  
11  
12  
13  
14  
15  
9
10  
16  
NOTE: Drawings for illustration purpose only. May not reflect actual product. Not to  
scale.  
DESCRIPTION  
PLUNGER VALVE (HOSE O-RING & STEP WASHER INCLUDED)  
HOSE O-RING  
REF. NO.  
QTY. SPARE PART NO.  
9
2
10747  
10262  
10745  
10256  
10255  
10744  
10253  
10  
11  
12  
13  
14  
15  
STEP WASHER  
STRAINER NUT  
FLAT STRAINER RUBBER WASHER  
THREADED STRAINER CONNECTOR  
STRAINER GRID  
LARGE STRAINER (COMBINATION OF STRAINER NUT, FLAT  
STRAINER RUBBER WASHER, THREADED STRAINER  
CONNECTOR & STRAINER GRID)  
16  
2
10746  
Page 6  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
STRAINER & PLUNGER VALVE SET-UP  
The Krystal Clear™ filter pump assembly includes two strainer-control  
mechanisms that are to be installed in the pool liner’s two pre-cut holes. The  
strainer grid prevents large objects from jamming and/or damaging the filter  
pump and the plunger valve assembly prevents water from flowing into the  
filter pump while the filter cartridge is being placed or cleaned. For Easy  
Set™ Pools, install the strainer and plunger valve before inflating the pool  
liner top ring.  
1. Grasp the strainer and plunger valve  
1
mechanism.  
2
2. In a counter-clockwise motion unscrew  
plunger valve union from the threaded  
strainer connector (14). Be careful not  
to lose the step rubber washer (11).  
Place the plunger valve on the ground  
1
in a safe place (see drawing 1).  
3. In a counter-clockwise motion unscrew  
the strainer nut (12) from the threaded  
connector (14). Leave the flat  
2
3
INSIDE  
LINER WALL  
washer (13) on the connector (14).  
4. From the inside of the pool liner insert  
the connector (14) into one of the  
pre-cut holes with the washer remaining  
on the connector to be placed against  
the inside of the liner wall.  
5. With the flat side of the strainer nut (12)  
facing the outside wall of the liner in a  
clockwise motion screw the strainer  
nut (12) back onto the threaded  
12  
13 14 15  
connector (14) (see drawing 2). Before  
assembly, lubricate the threads with a  
petroleum jelly.  
1
6. Finger tighten the strainer grid (15) and  
the strainer nut (12) onto the threaded  
connector (14).  
2
7. Grasp the plunger valve assembly. Make  
sure the step washer (11) is in place.  
8. In a clockwise motion screw the plunger  
valve union back onto the threaded  
connector (14) (see drawing 3).  
4.1  
INSIDE  
LINER  
WALL  
1
2
9. Examine the plunger valve to see if the  
handle is pushed fully down to the "0/1"  
position. If not, then grasp the handle at  
the top and push down turning the  
handle in a clockwise direction until the  
plastic protruding notch anchors in  
the "0/1" position. This will prevent  
water from flowing out during filling  
(see drawings 4.1 & 4.2).  
4.2  
10. Repeat steps 1 through 9 for the 2nd  
liner pre-cut hole.  
11. The pool liner is now ready to fill with  
water. Consult the above-ground-pool  
owner’s manual for filling instructions.  
Page 7  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
FILTER PUMP HOSE CONNECTION SET UP  
1. Remove the Krystal Clear™ filter pump and hoses from the packaging.  
2. Place the filter pump in a location for hose (8) connections to the plunger valve  
assemblies.  
Note: Some regional regulations may require the filter pump to be  
mounted on a stationary platform. There are two mounting holes located  
in the pump base for this reason. Consult your local authorities for  
filter-pump mounting requirements.  
3. Grasp the two pump hoses (8) and connect the hose nuts to the filter pump.  
4. In a counter-clockwise motion unscrew the threaded filter housing collar (1)  
from the filter housing. Place it in a safe place.  
5. The Filter Pump is an airtight system. In a counter-clockwise motion turn both  
air release valves (2 & 7) 1 - 2 turns to open. DO NOT remove air release  
valves as water will expel with force if the motor is turned on and injury  
may occur.  
6. Grasp and remove the filter housing cover (4). Check to see if a cartridge is  
inside the housing. If yes, replace the cover, finger tighten the housing collar (1)  
back onto the filter housing.  
7. Gently finger tighten the sediment release valve located at the bottom of the  
housing to be sure that water does not leak out.  
8. When the pool is filled connect the hose from the bottom of the filter housing to  
the highest strainer assembly. The hose connection is made at the bottom of  
the plunger valve assembly. Use the hose nut to attach the hose.  
9. Connect the 2nd hose to the middle of the motor housing and to the remaining  
liner connection.  
WARNING  
Position this product away from pool to prevent a child from  
climbing the pool.  
WATER LEVEL  
PLUNGER VALVE  
ASSEMBLY  
HOSE NUT  
OUTLET HOSE  
STRAINER  
FILTER HOUSING  
COVER  
INSIDE  
LINER WALL  
AIR RELEASE  
VALVE  
FILTER HOUSING  
COLLAR  
STRAINER  
MOTOR  
HOUSING  
FILTER CARTRIDGE  
INSIDE  
INLET HOSE  
POWER CORD  
HOSE O-RING  
OUTSIDE  
LINER WALL  
(ILLUSTRATION NOT TO SCALE)  
Page 8  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
OPERATING INSTRUCTIONS  
1. Make sure the filter pump switch is "OFF". The switch is located on the motor  
housing.  
2. Connect the power cord to a GFCI protected electrical outlet.  
WARNING  
Risk of electric shock. Connect this product only to a grounding type  
receptacle protected by a ground-fault circuit interrupter (GFCI) or residual  
current device (RCD). Contact a qualified electrician if you cannot verify  
that the receptacle is protected by a GFCI/RCD. Use a qualified electrician  
to install the GFCI/RCD, which has a maximum rate of 30mA. Do not use a  
portable residual current device (PRCD).  
IMPORTANT  
To prevent air lock, open the lower plunger valve (connected inlet hose)  
first and then the upper plunger valve (connected outlet hose). Open air  
release valves, wait until water starts to flow out of the air release valves,  
close air release valves.  
3. Grasp a plunger valve handle. Turn the handle counter-clockwise, pull up until  
it stops, and then turn it clockwise until the metal protruding notch anchors in  
the "0/1" position. Repeat for the 2nd plunger valve. This opens the valves to  
allow water to flow into the filter pump.  
4. With water flowing into filter pump, the water pressure will allow the air trapped  
inside to escape from the air release valves (2 & 7). When all the air has  
escaped water will flow out of the valves (2 & 7). When this occurs gently finger  
tighten the valves (2 & 7) in a clockwise direction.  
5. Turn the switch "ON". The filter pump is now filtering the water.  
6. Operate the filter pump until the desired water clarity is obtained.  
FILTER CARTRIDGE CLEANING OR REPLACEMENT  
It is recommended that the filter cartridge be replaced at least  
every 2 weeks.  
1. Make sure the filter pump is turned off, and disconnect the power cord from the  
electrical outlet.  
2. Grasp a plunger valve handle. Turn the handle counter-clockwise, push down  
until it stops and then turn it clockwise until the plastic protruding notch anchors  
in the "0/1" position. Repeat for the 2nd plunger valve. This prevents the water  
from flowing out of the pool.  
3. Gently turn the top air release valve 1-2 turns in a counter-clockwise direction.  
This will allow the housing cover to be easily removed.  
4. In a counter-clockwise direction remove the filter housing collar (1). Place it in a  
safe location.  
5. Remove the housing cover (4).  
Page 9  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
FILTER CARTRIDGE CLEANING OR REPLACEMENT (continued)  
6. Remove the "OLD" filter cartridge.  
7. Examine the inside of the filter housing.  
8. If dirt or sediment is located on the bottom of the housing then:  
A. In a counter-clockwise motion gently unscrew and remove the sediment  
valve (2) located at the bottom of the housing. Place it in a safe place.  
B. With a bucket of water or a garden hose pour water into the housing  
flushing out the sediment.  
C. In a gentle clockwise motion return the sediment valve (2) to its location.  
Do not over-tighten.  
9. Place a new cartridge filter in the housing.  
10. Return the housing cover (4) to its position and in a clockwise direction rescrew  
the housing collar (1) onto the filter housing.  
11. Turn both plunger valve handles in a counter-clockwise direction, pull up until  
they stop, and then turn them clockwise until the metal protruding notch  
anchors in the "0/1" position.  
12. When the trapped air has escaped through the air release valve gently  
retighten the valve (2) in a clockwise direction.  
13. Reconnect the power cord.  
14. Turn the pump "ON".  
FILTER PUMP STATIONARY MOUNTING OPTION  
Some countries, especially in the European community, require the filter-pump to  
be secured to the ground or to a base in a permanent upright position. Check your  
local authorities to determine if there is a regulation in your area regarding  
above-the-ground swimming pool filter-pumps. If yes, then the filter-pump can be  
mounted to a platform using the two holes located in the base. See drawing below.  
The filter-pump can be mounted on a cement base or onto a wooden platform to  
prevent accidental falling over. Total assembly must exceed 18kg. The European  
norm EN 60335-2-41 requires this product be secured to the ground or to a base.  
1. The mounting holes are 6.4 mm in diameter and spaced 165 mm apart.  
2. Use two bolts and lock nuts with a maximum of 6.4 mm in diameter.  
Page 10  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
POOL CARE AND CHEMICALS  
All pools require care to keep the water clear and hygienically clean. With  
proper chemical control, your filter will help attain this objective. Consult your  
pool supply dealer for instructions regarding the proper use of chlorine,  
algaecide and other chemical agents required for sparkling clear water.  
Keep pool chemicals away from children.  
Do not replenish chemicals in pool while pool is occupied. Skin or eye irritations  
could occur.  
Daily pH checking and chemical treatment of the water is very important and  
can not be overemphasized. Chlorine, algaecide and maintenance of proper pH  
levels are required when filling the pool as well as during the season. Consult  
your local swimming pool supply store for instructions.  
The season's first filling of the pool may have brackish water requiring extra  
water additives and extra filter changes. Do not allow swimming in pool until the  
pH level is balanced. Consult your local swimming pool supply store for  
instructions.  
Keep spare filter cartridges on hand. Replace cartridges every two weeks.  
Chlorinated water may damage lawns, gardens or shrubbery as children play  
in the pool and splash water outside the pool. Lawn areas underneath the  
pool liner will be destroyed. Note that some types of grass may grow through  
the liner but function is not affected.  
Filter run time depends on pool size, weather and usage level. Experiment with  
various run times so as to produce clean clear water.  
CAUTION  
Concentrated chlorine solutions may damage the pool liner. Always  
follow the chemical manufacturer’s directions, and the health and hazard  
warnings.  
Page 11  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
LONG TERM STORAGE  
1. Before emptying your pool for long term storage, or relocation, be sure the  
water is directed towards an acceptable drain water receptacle away from the  
house. Check local regulations for specific directions regarding disposal of  
swimming pool water.  
2. Disconnect power cord from electrical outlet.  
3. After pool is empty of all water disconnect all hoses from pump and plunger  
valves and remove strainers from pool wall.  
4. Drain all water from inside filter pump.  
5. Leave filter pump pieces & hoses outside to thoroughly air dry.  
6. Twist the plunger collar counter-clockwise removing the water flow control  
mechanism from the plunger housing.  
7. Coat the following O-rings and washers with petroleum jelly for long term  
storage:  
Air release valve & sediment O-rings (3).  
Filter housing cover O-ring (5).  
Pump hose O-rings (10).  
Strainer valve assembly step washers (11).  
Flat strainer rubber washers (13).  
8. Discard "OLD" used filter cartridge. Have 1-2 new cartridges available for next  
season’s use.  
9. Place all dry pieces in the original packaging for storage or place in an airtight  
plastic bag.  
10. Store the filter pump and accessories in a dry, cool storage location.  
Page 12  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
TROUBLESHOOTING GUIDE  
TROUBLE  
CHECK  
POSSIBLE SOLUTIONS  
FILTER MOTOR  
FAILS TO START  
• Not plugged in.  
Filter cord must be plugged into a 3 wire  
outlet that is protected by a Class A  
Ground Fault Circuit Interrupter, or RCD.  
• Fuse box needs checking.  
• GFCI/RCD circuit breaker  
tripped.  
• Reset circuit breaker. If circuit breaker  
trips repeatedly, your electrical system  
may have a defect. Turn off circuit  
breaker and call an electrician to  
correct the problem.  
• Motor too hot and overload protection  
shut motor off. Let motor cool down.  
FILTER DOESN’T  
CLEAN POOL  
• Improper chlorine or pH  
levels.  
• Filter cartridge dirty.  
• Cartridge damaged.  
• Excessively dirty pool.  
• Strainer screen restricting  
flow.  
Adjust chlorine and pH level. Consult  
your local swimming pool supply stores.  
• Clean or replace cartridge.  
• Check for holes in cartridge. Replace  
if damaged.  
• Operate filter for longer periods.  
• Clean strainer screen at pool wall inlet.  
FILTER DOESN’T  
PUMP WATER OR  
FLOW IS VERY  
SLOW  
• Inlet/discharge clogged.  
• Air leak on intake line.  
• Scale or buildup on cartridge.  
• Excessively dirty pool.  
• Filter cartridge dirty.  
• Look for obstructions in intake hose or  
discharge hose inside pool wall.  
• Tighten hose nuts, check hoses for  
damage, check pool water level.  
• Replace cartridge.  
• Clean cartridge more often.  
• Clean inside plunger valve.  
Pull valve handle to full upright position.  
PUMP DOESN’T  
WORK  
• Low water level.  
• Fill pool to correct water level.  
• Clean strainer screens at pool inlet.  
• Tighten hose nuts, check hose for damage.  
• Check & clear any sticks or leaves in  
intake to pump.  
• Strainer screen plugged up.  
• Air leak on intake hose.  
• Faulty motor or impeller  
jammed.  
• Air lock inside cartridge  
chamber.  
Turn & pull valve handle to full upright  
position.  
TOP COVER  
LEAKING  
• O-ring missing.  
• Cover not tight.  
• Filter cartridge dirty.  
• Remove cover & check for O-ring.  
• Tighten cover (Manually).  
• Replace or clean cartridge.  
HOSE LEAKING  
AIR LOCK  
• Hose nuts.  
• Tighten/reinstall hose nut.  
• Pump housing and inlet hose  
air trapped.  
• Inlet and outlet hoses  
connection reversed.  
Open air release valves, wait until water  
starts to flow out of the air release  
valves, close air release valves.  
• Lower position of pool outlet connect  
to filter pump water inlet, upper  
position of pool inlet connect to filter  
pump water outlet.  
IMPORTANT  
If you continue to experience difficulty, please contact our  
Consumer Service Department for assistance. See back cover for  
contact information.  
Page 13  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
COMMON POOL PROBLEMS  
PROBLEM  
DESCRIPTION  
CAUSE  
REMEDY  
ALGAE  
• Greenish water.  
• Green or black  
spots on pool liner.  
• Pool liner is  
• Chlorine and pH levels • Super chlorinate with shock  
need adjustment.  
treatment. Correct pH to your  
pool store's recommended  
level.  
slippery and/or has  
a bad odor.  
• Vacuum pool bottom.  
• Maintain proper chlorine  
level.  
COLORED  
WATER  
• Water turns blue,  
brown, or black  
when first treated  
with chlorine.  
• Copper, iron or  
manganese in water  
being oxidized by the  
added chlorine.  
Common.  
• Adjust pH to recommended  
level.  
• Run filter until water is clear.  
• Clean cartridge frequently.  
SUSPENDED  
MATTER IN  
WATER  
• Water is cloudy or  
milky.  
• "Hard water" caused  
by pH level being too  
high.  
• Chlorine content is low.  
• Foreign matter in  
water.  
• Correct pH. Check with pool  
dealer for water treatment.  
• Check for proper chlorine  
level.  
• Clean or replace your filter.  
CHRONIC  
LOW WATER  
LEVEL  
• Level is lower than  
on previous day.  
• Rip or hole in pool  
liner or hoses. Tighten  
caps.  
• Repair with patch kit.  
• Finger tighten all caps.  
SEDIMENT  
ON POOL  
BOTTOM  
• Dirt or sand on  
pool floor.  
• Heavy use, getting in  
and out of pool.  
• Use Intex pool vacuum to  
clean bottom of pool.  
SURFACE  
DEBRIS  
• Leaves, insects  
etc.  
• Pool too close to  
trees.  
• Use Intex pool skimmer.  
Page 14  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
GENERAL AQUATIC SAFETY  
Water recreation is both fun and therapeutic. However, it involves  
inherent risks of injury and death. To reduce your risk of injury, read  
and follow all product, package and package insert warnings and  
instructions. Remember, however, that product warnings, instructions  
and safety guidelines cover some common risks of water recreation,  
but do not cover all instances or risk and or danger.  
For additional safeguards, also familiarize yourself with the following  
general guidelines as well as guidelines provided by nationally  
recognized Safety Organizations:  
• Demand constant supervision.  
• Learn to swim.  
Take the time to learn CPR and first aid.  
• Instruct anyone who is watching your children about potential pool  
hazards and about the use of protective devices such as locked doors,  
barriers, etc.  
Teach children what to do in case of an emergency.  
• Always use common sense and good judgement when enjoying any  
water activity.  
• Supervise, Supervise, Supervise.  
Page 15  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
LIMITED WARRANTY  
PARTS LIST  
Your Krystal Clear™ Filter-Pump has been manufactured using the highest quality  
materials and workmanship. All Intex products have been inspected and found free of  
defects prior to leaving the factory. This Limited Warranty applies only to the Krystal  
Clear™ Filter-Pump.  
The provisions of this Limited Warranty apply only to the original purchaser and is not  
transferable. This Limited Warranty is valid for a period of one (1) year from the date of the  
initial retail purchase. Keep your original sales receipt with this manual, as proof of  
purchase will be required and must accompany warranty claims or the Limited Warranty is  
invalid.  
If a manufacturing defect is found within this one (1) year period, please contact the  
appropriate Intex Service Center listed in this manual. The Service Center will determine  
the validity of the claim.  
IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN  
NO EVENT SHALL INTEX, THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE  
TO THE BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL  
DAMAGES OR LIABILITIES.  
This Limited Warranty does not apply if the Krystal Clear™ Filter-Pump is subject to  
negligence, abnormal use or operation, accident, improper operation, improper voltage or  
current contrary to operating instructions, or to damage by circumstances beyond Intex’s  
control, including but not limited to, ordinary wear and tear and damage caused by  
exposure to fire, flood, freezing, rain, or other external environmental forces. This Limited  
Warranty applies only to those parts and components sold by Intex. The Limited Warranty  
does not cover unauthorized alterations, repairs or disassembly by anyone other than Intex  
Service Center personnel.  
The costs associated with the loss of pool water, chemicals or water damage are not  
covered by this warranty. Injury or damage to any property or person is not covered by this  
warranty.  
Page 16  
SAVE THESE INSTRUCTIONS  
 
(110) MODEL 634 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/31/2007  
110  
For service questions or to order replacement parts, please contact the appropriate office  
questions.  
AREAS  
LOCATION  
AREAS  
LOCATION  
COMEXA S.A  
SAN IGNACIO 0201, PARQUE  
INDUSTRIAL PORTEZUELO,  
QUILICURA, SANTIAGO, CHILE  
TEL: 56-2-339 9000  
CHILE / ARGENTINA /  
PERU / URUGUAY  
ASIA  
INTEX DEVELOPMENT CO. LTD.  
8TH FLOOR,  
DAH SING FINANCIAL CENTRE,  
108 GLOUCESTER ROAD,  
WANCHAI, HONG KONG  
TEL: 852-28270000  
FAX: 56-2-339 9022  
FAX: 852-23118200  
SAUDI ARABIAN MARKETING &  
AGENCIES CO. LTD.  
PRINCE AMIR MAJED STREET,  
AL-SAFA DISTRICT. JEDDAH,  
KINGDOM OF SAUDI ARABIA  
TEL: 966-2-693 8496  
INTEX TRADING B.V.  
POSTBUS 1075, 4700 BB ROOSENDAAL,  
THE NETHERLANDS  
TEL: 31-(0)165-593939  
SAUDI ARABIA  
EUROPE  
FRANCE  
GERMANY  
ITALY  
FAX: 31-(0)165-593969  
FAX: 966-2-271 4084  
INTEX SERVICE (FRANCE) SAS  
52, ROUTE NATIONALE  
39190 BEAUFORT, FRANCE  
TEL: 08 90 71 20 39 (0.15 TTC/min)  
FAX: 03 84 25 18 09  
STEINBACH GMBH GERMANY  
AN DER WELLE 4  
60322 FRANKFURT  
STEINBACH GMBH AUSTRIA  
AISTINGERSTRAßE 2  
4311 SCHWERTBERG  
TEL: 0800 468397665  
FAX: 07262 61439-0  
INTEX TRADING S.R.O.  
BENESOVSKA 23,  
101 00 PRAHA 10  
CZECH REPUBLIC  
TEL: 420-2-717 32247  
FAX: 420-2-673 12552  
N.V. NICOTOY S.A.  
AUSTRIA  
CZECH REPUBLIC /  
EASTERN EUROPE  
TEL: 0800 468397665  
FAX: 07262 61439-0  
A & A MARKETING SERVICE  
OFFICE: VIA DEI MESTIERI 8, 20049  
CONCOREZZO, MILANO - ITALY  
TEL: 39-039-6886260  
BELGIUM  
DENMARK  
MOESKROENSESTEENWEG 383 C,  
8511 AALBEKE  
TEL: 0800 92088  
FAX: 39-039-6043603  
WAREHOUSE: C/O ALVI, VIALE DELLA  
REPUBBLICA 10 - 27100 PAVIA - ITALY  
TOY BROKERS LTD  
MARKETING HOUSE,  
BLACKSTONE ROAD  
HUNTINGDON, CAMBS.  
PE29 6EF. UK  
TEL: 01480 414361  
FAX: 32-56.20.37.61  
K.E. MATHIASEN A/S  
SINTRUPVEJ 12  
DK-8220 BRABRAND  
DENMARK  
TEL: +45 89 44 22 00  
FAX: +45 86 24 02 39  
LEKSAM AB  
BRANDSVIGSGATAN 6,  
S-262 73 ÄNGELHOLM,  
SWEDEN  
TEL: +46 431 44 41 20  
FAX: +46 431 190 35  
NORSTAR AS  
PINDSLEVEIEN 1  
N-3221 SANDEFJORD  
NORWAY  
TEL: +47 33 48 74 10  
UK  
FAX: 01480 414761  
SWEDEN  
NORWAY  
FINLAND  
RUSSIA  
GWM AGENCY  
GARTEN-U. WOHNMÖBEL  
RÄFFELSTRASSE 25  
POSTFACH  
CH-8045 ZURICH/SWITZERLAND  
TEL: + 41 - (0)900 - 455 456  
FAX: 41 44 455 50 65  
KOKIDO BVI LIMITED  
C/PLOMO 5-7, NAVE 19 POLÍGONO  
INDUSTRIAL AIMAYR SAN MARTÍN DE  
LA VEGA 28330 MADRID SPAIN  
TEL: 34-90-2351045  
SWITZERLAND  
SPAIN / PORTUGAL  
FAX: +47 33 48 74 11  
NORSTAR OY  
RUUKINTIE 20  
FIN-02330 ESPOO  
FINLAND  
TEL: +358 9 8190 530  
FAX: +358 9 8190 5335  
LLC BAUER  
KIEVSKAYA STR., 20,  
121165 MOSCOW, RUSSIA  
TEL: 095-249-9400/8626/9802  
FAX: 095-742-8192  
KATHAY HASTER  
UL. LUTYCKA 3,  
60-415 POZNAN  
TEL: +48 61 8498 381/380  
FAX: +48 61 8474 487  
RECONTRA LTD.  
H-1113 BUDAPEST, DARÓCZI ÚT 1-3,  
HUNGARY  
FAX: 34-91-6912709  
HUNTER OVERSEAS PTY LTD  
LEVEL 1, 225 BAY STREET,  
BRIGHTON, VICTORIA  
AUSTRALIA  
AUSTRALIA  
TEL: 61-3-9596-2144 or 1800-224-094  
FAX: 61-3-9596-2188  
HAKA NEW ZEALAND LIMITED  
UNIT 5, SENTINEL PARK,  
25 AIRBORNE ROAD, ALBANY  
PO BOX 302171,  
NORTH HARBOUR,  
AUCKLAND 1330  
NEW ZEALAND  
TEL: 649-4159213  
FAX: 649-4159212  
FIRST GROUP TRADING  
AL MOOSA GROUP BUILDING, 1ST  
FLOOR, OFFICE 102 & 103, UMM HURAIR  
ROAD, KARAMA, DUBAI, UAE  
TEL: 00971-4-3373322  
NEW ZEALAND  
POLAND  
HUNGARY  
BRAZIL  
MIDDLE EAST  
REGION  
TEL: +361 372 5200/113  
FAX: +361 209 2634  
KONESUL MARKETING & SALES LTDA  
RUA INÁCIO BORBA, 835 - CEP. 04715-020,  
CHÁCARA SANTO ANTONIO - SÃO  
PAULO - SP - BRASIL  
TEL: 55 (11) 5183 8866  
FAX: 55 (11) 5183 8866  
FAX: 00971-4-3375115  
WOOD & HYDE  
15-17 PACKER AVENUE, INDUSTRIA 2,  
CAPE TOWN, SOUTH AFRICA 7460  
TEL: 27-21-0800-204-692  
FAX: 27-21-505-5600  
SOUTH AFRICA  
Page 17  
SAVE THESE INSTRUCTIONS  
 

Ingersoll Rand Fitness Equipment MHD56298 User Manual
JBL MP3 Docking Station radial micro User Manual
John Deere Radio OMPFP12436 User Manual
JVC CD Player GET0253 003A User Manual
JVC CRT Television HD 56FH96 User Manual
JVC MP3 Player XA A50CL User Manual
JVC Stepper Machine CS V6934 User Manual
Kenwood Kitchen Grill SM630 User Manual
Kodak Digital Camera CD153 User Manual
Kodak Printer RP 30 User Manual