Ingersoll Rand Heat Pump WLM2203A X1 User Manual

OPERATOR’S MANUAL  
WLM2203A-X  
INCLUDING: SPECIFICATIONS, SERVICE KITS, GENERAL INFORMATION, PARTS, TROUBLESHOOTING  
INCLUDE MANUAL: S-633 GENERAL INFORMATION (PN 97999-625)  
RELEASED:  
REVISED:  
(REV. G)  
5-3-99  
8-1-11  
2” AIR MOTOR  
3:1 RATIO  
WLM2203A-XX  
0 - 375 P.S.I. RANGE  
TWO-BALL PUMP SERIES  
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,  
OPERATING OR SERVICING THIS EQUIPMENT.  
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.  
SERVICE KITS  
PUMP DATA  
Use only genuine AROR replacement parts to assure compatible  
pressure rating and longest service life.  
637224 Pump Rebuild Kit. Includes the necessary soft parts for  
normal service of the entire pump.  
MODEL WLM2203A-XX  
Air Inlet (female)  
See “Specifications”  
18-1/32”  
SPECIFICATIONS  
(458.0 mm)  
Material Outlet (female)  
See “Specifications”  
NOTE: Pump is assembled  
with material outlet located  
180_ from the air inlet.  
Model Series (Refer to option chart) . . . . . . . WLM2203A-XX  
Type . . . . . . . . . . . . . . . . . . . . . . . . . Air Operated, Two Ball,  
Double Acting Oil Pump  
Ratio . . . . . . . . . . . . . . . . . . . . . . . . . 3:1  
Air Motor Diameter . . . . . . . . . . . . . . 2” (5.08 cm)  
Stroke . . . . . . . . . . . . . . . . . . . . . . 3” (7.62 cm)  
Air Inlet (female)  
models WLM2203A-X1 . . . . . . 1/4 - 18 N.P.T.F. - 1  
models WLM2203A-X2 . . . . . . Rc 1/4 (1/4 - 19 BSP Taper)  
Material Inlet (female)  
1-5/16”  
(33.4 mm)  
6-29/32”  
(175 mm)  
2” N.P.T. Bung Adapter  
Material Inlet (female)  
See “Specifications”  
Models WLM2203A-1X  
models WLM2203A-X1 . . . . . . 3/4 - 14 N.P.T.  
models WLM2203A-X2 . . . . . . Rp 3/4 (3/4 - 14 BSP Parallel)  
Material Outlet (female)  
‘‘B”  
models WLM2203A-X1 . . . . . . 1/2 - 14 N.P.T.  
models WLM2203A-X2 . . . . . . Rp 1/2 (1/2 - 14 BSP Parallel)  
Pump Construction . . . . . . . . . . . . Carbon Steel  
Dimensional Data . . . . . . . . . . . . . . . see “Pump Data”  
Weight . . . . . . . . . . . . . . . . . . . . . . . . see chart  
‘‘A”  
Figure 1  
PERFORMANCE  
Air Inlet Pressure Range . . . . . . . . . . 0 - 125 p.s.i. (0 - 8.6 bar)  
Fluid Pressure Range . . . . . . . . . . . . 0 - 375 p.s.i. (0 - 25.9 bar)  
Maximum Rec’d Cycles / Minute . . . . 125  
Displacement In3 Per Cycle . . . . . . . . 6.2  
Volume / Cycle . . . . . . . . . . . . . . . . . . 3.46 oz. (102.28 ml)  
Cycles Per Gallon (Liter) . . . . . . . . . . 37 (9.8)  
Maximum Working Flow Rate . . . . . . 6 g.p.m. (23 l.p.m.)  
Maximum Flow Rate . . . . . . . . . . . . . 9 g.p.m. (34 l.p.m.)  
Noise Level @ 100 p.s.i. - 124 c.p.m. . . 80 db(A)*  
Accessories Available . . . . . . . . . . . . 61113 Wall Mount Bracket  
66073-1 Air Line Connection Kit  
Material Inlet (female)  
See “Specifications”  
Models WLM2203A-3X, -4X, -5X  
NOTE: Dimensions are shown in inches and (mm), supplied for reference only and are typically  
rounded up to the nearest 1/16 inch.  
MODEL  
“A” (mm)  
“B” (mm)  
N / A  
WEIGHT (kg)  
11 (4.99)  
13.5 (6.12)  
14.4 (6.53)  
15 (6.80)  
WLM2203A-1X  
N / A  
WLM2203A-3X 40-1/16” (1017.3)  
22-1/32” (559.3)  
*
ThepumpsoundpressurelevelhasbeenupdatedtoanEquivalentContinuousSound  
Level (L ) to meet the intent of ANSI S1. 13-1971, CAGI-PNEUROP S5.1 using four  
WLM2203A-4X 49-13/16” (1265.0) 31-25/32” (806.9)  
WLM2203A-5X 57-7/16” (1458.6) 39-13/32” (1000.6)  
Aeq  
microphone locations.  
IMPORTANT  
This is one of two documents which support the pump. Replace-  
ment copies of these forms are available upon request.  
= WLM2203A-XX MODEL OPERATOR’S MANUAL  
- S-633 GENERAL INFORMATION LUBRICATION PISTON PUMPS  
PATENTED  
INGERSOLL RAND COMPANY  
209 NORTH MAIN STREET -- BRYAN, OHIO 43506  
E2011  
(800) 495--0276 D FAX FAX(800) 892--6276  
 
PARTS LIST / WLM2203A-XX  
1
6
7
19  
20  
21  
22  
2
3
8
9
4
5
23  
24  
25  
10  
34  
UPPER SECTION  
11  
LOWER SECTION  
26  
27 ,  
38  
28 H  
H
. 36  
37  
29 ,  
5
9
8
4
12  
30  
31  
48  
13  
7
32  
33 ,  
6
14  
13  
3
41  
15  
16  
17  
42  
43  
18  
47  
44  
45  
46  
H Lubricate with Gadus S2 U1000 grease at assembly.  
. TORQUE REQUIREMENTS ,  
(27, 36) 9 Nm (79.7 in. lbs)  
(29, 33) 88 - 95 Nm (64.9 - 70.1 ft lbs)  
49  
39  
40  
Figure 2  
WLM2203A-XX  
Page 3 of 4  
 
PLACING INTO SERVICE  
AIR AND LUBRICATION REQUIREMENTS  
should be used on thread connection. Tighten all fittings. Use cau-  
tion not to damage threads.  
Filtered air willhelpextend thelife of thepump, allowingthepump to op-  
erate more efficiently and yield longer service life to moving parts and  
mechanisms.  
OPERATION  
Installanairlinefiltertoprovidegoodqualitycleananddryair.Install  
it up stream from the regulator.  
START-UP  
Use an air regulator on the air supply to control the pump cycle rate.  
Install the regulator as close as possible to the pump.  
Inmostinstallations, lubricationisnotrequired. Ifthepumpneedsto  
havelubrication,installanairlinelubricatorandsupplyitwithagood  
grade of non-detergent oil or other lubricant compatible with Nitrile  
seals and set at a rate not to exceed one drop per minute.  
1. Turn the air regulator to “0” pressure setting.  
2. Immerse the lower pump end into the material.  
3. Open the dispensing device.  
4. Start the pump cycling slowly by raising the pressure to 1.4 - 2.1 bar  
(20 - 30 p.s.i.).  
5. Close the dispensing device. Allow the pump to stall and build line  
pressure. Check for anyleaks and tighten fittingsas needed. Adjust  
pressure as required for the application.  
INSTALLATION  
Mount and secure the pump as required for the application.  
Attach a ground wire from the pump ground screw to a suitable  
ground.  
SHUTDOWN  
Disconnecttheairsupplyfromthepumpifitistobeinactiveforafew  
Connectafluidhosetothepumpoutlet.Inmostcasesapipesealant  
hours. Open the dispensing device to relieve line pressure.  
SERVICE  
2. Locate the valve chamber on the (11) cylinder where the 3/8’’ dia.  
hole is located and install one of the (4) sleeves. Insert the (7) spool  
from the opposite end. Next, install the remaining sleeve and spool.  
3. Replace the (3) track gasket and install (2) cap.  
PUMP DISASSEMBLY / REASSEMBLY  
NOTICE: The unique design of this pump allows for quick basic pump  
service without total removal from the drum (refer to the views below).  
DISASSEMBLY - Allthreadsarerighthand.Refertofigure2.These  
proceduresarefortheinstallationofrepairkitparts.Disconnectair  
supply and relieve all system pressure prior to servicing. Carefully  
removetheparts,inspectpartsfordamage,nicksorexcessivewearand  
determine if any parts will need replacement.  
Follow the three disassembly steps in the detail views below and place  
the pump on a clean bench.  
1. Remove(1) bolts. Remove(18)packing, (17)bushingand(16) “Oring.  
2. Remove (36) adapter, releasing (10) muffler.  
3. Grasp the (11) cylinder and remove the (20, 14) piston assembly.  
4. Remove(15) lower capand(3) trackgasket. Remove (12) retaining  
ring and (48) washer, then pull (14) piston off (20) piston rod.  
5. Remove (2) cap and (3) track gasket. Push on the large o.d. end of  
the(7)spooltoremovethe(4)sleeve.Grabthenoseof(7)spooland  
pull out. Repeat for other sleeve and spool.  
4. Replacethe(13) pistonU” cups(refer tofigure 2for proper orienta-  
tion). Replacethe(19) “O” ringandassemble(14) pistonto(20)pis-  
ton rod and retain with (48) washer and (12) retaining ring.  
5. Install the (20, 14) piston assembly using great care to collapse the  
outer lip of the second “U” cup, allowing it to slip into the cylinder.  
6. Replace the (3) track gasket and install the (15) cap. Install the (16)  
“O” ring onto the piston rod, replace (17) bushing and (18) packing.  
7. Replace the (25) “O” ring and re-attach the (24) inner check.  
8. Slide the pump assembly back into the (26) base / lower pump sec-  
tion.Pressthesectionstogetherandaligntheairinletandpumpout-  
letasrequiredandreplacethefour(1)boltsand(27)nuts(tightento  
9 Nm (79.7 in. lbs).  
TROUBLE SHOOTING  
If the pump will not cycle or will not deliver material.  
Becertaintocheckfornon-pumpproblemsincludingkinked,restric-  
tiveorpluggedinlet/outlethoseordispensingdevice.Depressurize  
the pump system and clean out any obstructions in the inlet / outlet  
material lines.  
REASSEMBLY - Thoroughly clean and lubricate all seals and  
bores with Shell Gadus S2 U1000 upon assembly. Replace all soft  
parts with new ones included in the repair kit.  
Note: Refer to the illustration (figure 2) for “U” cup lip seal direction.  
1. Replace the seals on both the (7) spools and (4) sleeves.  
Check all seals, including track gaskets.  
Check direction of “U” cup lips.  
PUMP DISASSEMBLY DETAIL  
A) Remove the four  
nuts from the base  
of the Air Motor.  
B) Grasp the lower motor cap  
and pull out the motor and  
upper section of the lower  
section.  
C) Unlock the (24) inner  
check from the piston rod.  
Figure 3  
Figure 4  
Figure 5  
PN 97999-865  
WLM2203A-XX  
Page 4 of 4  
 

Ingersoll Rand Air Compressor EP50 PE User Manual
Intellinet Network Solutions Network Router 524445 User Manual
Intermec Printer PF8D User Manual
Jensen Car Stereo System MP7610XMi User Manual
JVC Car Video System LVT1484 001B User Manual
Kenmore Air Conditioner 58075080 User Manual
Kenmore Refrigerator 10656824603 User Manual
KitchenAid Gas Grill Gas Range Architect Series II User Manual
KitchenAid Oven KEBS109ESS User Manual
Kramer Electronics Speaker SPK C613 User Manual